About Your System
35
E201C
SMI
initialization
failure. Power
cycle AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201D
Shutdown test
failure. Power
cycle AC.
BIOS shutdown test
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201E
POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory."
If the problem persists,
see "Getting Help."
E2020
CPU
configuration
failure. Check
screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting the
Processor(s)."
E2021
Incorrect
memory
configuration.
Review User
Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory."
E2022
General
failure during
POST. Check
screen
message.
General failure after video. Check screen for specific
error messages.
E2023
BIOS Unable to
mirror memory.
Check DIMMs.
The system BIOS could
not enable memory
mirroring because of a
faulty memory module or
an invalid memory
configuration.
See "Troubleshooting
System Memory."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 35 Tuesday, September 15, 2009 10:08 AM
Содержание PowerEdge T610
Страница 1: ...Dell PowerEdge T610 Systems Hardware Owner s Manual ...
Страница 23: ...About Your System 23 Figure 1 5 Power Supply Status Indicator 1 power supply status 1 ...
Страница 56: ...56 About Your System ...
Страница 154: ...154 Installing System Components ...
Страница 188: ...188 Jumpers and Connectors ...
Страница 190: ...190 Getting Help ...
Страница 205: ...Index 205 warranty 55 wet system troubleshooting 158 ...
Страница 206: ...206 Index ...