![Dell PowerEdge R630 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/dell/poweredge-r630/poweredge-r630_owners-manual_85469042.webp)
Table 24. Temperature specifications
Temperature
Specifications
Storage
–40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m
or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight
on the equipment.
NOTE: Maximum of 145 W 22 core processor
is supported in systems with eight 2.5-inches
drives, two PCI slot chassis, and 75 W single
wide active GPU.
Fresh air
For information about fresh air, see Expanded
Operating Temperature section.
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Table 25. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Operating
10% to 80% relative humidity with 29°C (84.2°F)
maximum dew point.
Table 26. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation
orientations).
Storage
1.88 G
rms
at 10 Hz to 500 Hz for 15 min (all six
sides tested).
Table 27. Maximum shock specifications
Maximum shock
Specifications
Operating
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes of 40 G for up
to 2.3 ms.
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms.
42
Содержание PowerEdge R630
Страница 1: ...Dell PowerEdge R630 Owner s Manual Regulatory Model E26S Series Regulatory Type E26S001 ...
Страница 10: ...Figure 1 Supported configurations for the PowerEdge R630 system Front panel 10 ...
Страница 205: ...Related Links Getting help Using system diagnostics Removing the system cover Installing the system cover 205 ...