Installing System Components
81
Installing a Non-redundant Power Supply
1
If you are installing a non-redundant power supply to replace redundant
power supplies, you will need to replace the power supply distribution
board with the power supply cage cover.
a
Remove the power supply distribution board. See "Removing the
Power Supply Distribution Board" on page 143.
b
Install the power supply cage cover by pressing the cover into the
power supply cage until the retention pins lock into place. See
Figure 3-41.
2
Slide the power supply into the back of the system until the power supply
release tab snaps into place. See Figure 3-8.
3
Install the two Phillips screws to secure the power supply to the system.
See Figure 3-8.
4
Depending on your system configuration, connect the following power
cables:
•
PWR1 connector on the system board
•
PWR2 connector on the system board
•
PWR3 connector on the system board
•
BP_PWR connector on the optional SAS/SATA backplane
•
Hard drives
•
Diskette drive
•
Tape backup unit
•
Optical drives
5
Install the processor shroud. See "Installing the Processor Shroud" on
page 74.
6
Install the expansion card shroud. See "Installing the Expansion Card
Shroud" on page 75.
7
Close the system. See "Closing the System" on page 70.
8
Place the system upright and on its feet on a flat, stable surface.
9
Reattach any peripherals, then connect the system to the electrical outlet.
10
Turn on the system and attached peripherals.
Содержание PowerEdge DR715
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge T605 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents Glossary 207 Index 223 ...
Страница 42: ...42 About Your System ...
Страница 62: ...62 Using the System Setup Program ...
Страница 158: ...158 Installing System Components ...
Страница 192: ...192 Troubleshooting Your System ...
Страница 204: ...204 Jumpers and Connectors ...
Страница 206: ...206 Getting Help ...
Страница 222: ...222 Glossary ...
Страница 229: ...Index 229 W warning messages 41 warranty 11 wet system troubleshooting 168 ...
Страница 230: ...230 Index ...