168
Troubleshooting Your System
2
Check the appropriate indicator on the NIC connector. See "NIC Indicator
Codes" on page 18.
•
If the link indicator does not light, check all cable connections.
•
If the activity indicator does not light, the network driver files might
be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC's
documentation.
•
Change the autonegotiation setting, if possible.
•
Use another connector on the switch or hub.
If you are using a NIC card instead of an integrated NIC, see the
documentation for the NIC card.
3
Ensure that the appropriate drivers are installed and the protocols are
bound. See the NIC's documentation.
4
Enter the System Setup program and confirm that the NICs are enabled.
See "Entering the System Setup Program" on page 43.
5
Ensure that the NICs, hubs, and switches on the network are all set to the
same data transmission speed. See the network equipment
documentation.
6
Ensure that all network cables are of the proper type and do not exceed the
maximum length.
If the problem persists,
see
"Getting Help" on page 205
.
Troubleshooting a Wet System
Problem
•
Liquid spilled on the system.
•
Excessive humidity.
Содержание PowerEdge DR715
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge T605 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents Glossary 207 Index 223 ...
Страница 42: ...42 About Your System ...
Страница 62: ...62 Using the System Setup Program ...
Страница 158: ...158 Installing System Components ...
Страница 192: ...192 Troubleshooting Your System ...
Страница 204: ...204 Jumpers and Connectors ...
Страница 206: ...206 Getting Help ...
Страница 222: ...222 Glossary ...
Страница 229: ...Index 229 W warning messages 41 warranty 11 wet system troubleshooting 168 ...
Страница 230: ...230 Index ...