22
About Your System
E123C
Planar LOM
PwrGd
Voltage regulator for the
integrated LOM has failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 205.
E1310
RPM Fan ##
RPM of specified cooling
fan is out of acceptable
operating range.
See "Troubleshooting
System Cooling
Problems" on page 172.
E1313
Fan
Redundancy
The system is no longer fan-
redundant. Another fan
failure will put the system at
risk of over-heating.
Check control panel LCD
for additional scrolling
messages (see
"Troubleshooting System
Cooling Problems" on
page 172).
Table 1-5.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions