36
About Your System
E2021
Incorrect
memory
configuration.
Review User
Guide.
Incorrect memory
configuration.
Check screen for specific
error messages.
See "Troubleshooting
System Memory" on
page 163.
E2022
General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
E2023
BIOS unable
to mirror
memory. Check
DIMMs.
The system BIOS could not
enable memory mirroring
because of a faulty memory
module or an invalid
memory configuration.
See "Troubleshooting
System Memory" on
page 163.
E2110
Multibit
Error on DIMM
##. Reseat
DIMM.
The memory module in slot
“##” has had a multi-bit
error (MBE).
See "Troubleshooting
System Memory" on
page 163.
E2111
SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory single-bit
error (SBE) logging and will
not log any more SBEs until
the system is rebooted.
"##" represents the
memory module implicated
by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 163.
E2113
Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC.
The system BIOS has
disabled memory mirroring
because it has determined
one half of the mirror has
had too many errors. "##
& ##" represents the
memory module pair
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 163.
Table 1-1. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions
Содержание DX6000