About Your System
E122E
On-board
regulator
failed. Call
support.
One of the on-board
voltage regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 189.
E1310
Fan ## RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside of the intended
operating range.
See "Troubleshooting
System Cooling
Problems" on page 161.
E1311
Fan module ##
RPM exceeding
range. Check
fan.
RPM of specified fan in
specified module is outside
of intended operating
range.
See "Troubleshooting
System Cooling
Problems" on page 161.
E1313
Fan
redundancy
lost. Check
fans.
The system is no longer fan
redundant. Another fan
failure would put the
system at risk of over-
heating.
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan"
on page 162.
E1410
System Fatal
Error
detected.
A fatal system error has
been detected.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 189.
E1414
CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out of
acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processor" on page 172
and "Troubleshooting
System Cooling
Problems" on page 161.
Table 1-1. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions