Specifications: Broadcom NetXtreme II Network Adapter User Guide
file:///T|/htdocs/NETWORK/BroadCom/71921/NetXtremeII/en/specs.htm[9/26/2012 3:29:56 PM]
Environmental Specifications
Table 11: BCM5708 Environmental Specifications
Condition
Operating Specification
Storage Specification
Temperature
0°C to 55°C (+32°F to +131°F)
–40°C to +85°C (–40°F to +185°F)
Relative humidity
5% to 85% (noncondensing)
40°C, 16 hour dwells at extremes
5% to 95% (noncondensing)
10°C/hour
Altitude
Up to 10,000 ft.
Up to 35,000 ft.
Shock
10g, 1/2 sine wave, 11 ms
60g, 1/2 sine wave, 11 ms
Vibration, peak to peak displacement 0.005 in. max (5 Hz to 32 Hz)
0.1 in. max (5 Hz to 17 Hz)
Vibration, peak acceleration
0.25g (5 Hz to 500 Hz)
(Sweep Rate = 1 octave/min.)
0.25g (5 Hz to 500 Hz)
(Sweep Rate = 1 octave/min.)
Table 12: BCM5709 Environmental Specifications
Parameter
Condition
Operating Temperature
0°C to 55°C
Air Flow Requirement (LFM)
0
Storage Temperature
–40°C to +65°C
Storage Humidity
5% to 95% condensing
Vibration and Shock
IEC 68, FCC Part 68.302, NSTA, 1A
Electrostatic/Electromagnetic Susceptibility EN 61000-4-2, EN 55024
Table 13: BCM957810A1006G Environmental Specifications
Parameter
Condition
Operating Temperature
0°C to 55°C
Air Flow Requirement (LFM)
0
Storage Temperature
–40°C to +65°C
Storage Humidity
5% to 95% condensing
Vibration and Shock
IEC 68, FCC Part 68.302, NSTA, 1A
Electrostatic/Electromagnetic Susceptibility IEC 801-2, 3, 4, 5
Table 14: BCM957810a1008G Environmental Specifications
Parameter
Condition
Operating Temperature
0°C to 55°C
Air Flow Requirement (LFM)
50
Storage Temperature
–40°C to +65°C
Storage Humidity
5% to 95% condensing
Vibration and Shock
IEC 68, FCC Part 68.302, NSTA, 1A
Electrostatic/Electromagnetic Susceptibility IEC 801-2, 3, 4, 5
Please read all
Restrictions and Disclaimers
.
Back to Contents Page