Figure 39. Installing drive blank into the mid drive carrier
Next step
Follow the procedure listed in
After working inside your system
Removing the drive carrier from the mid drive tray
Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
From the management software, prepare the drive for removal. Wait until the indicators on the drive carrier signal that the drive can
be removed safely. For more information, see the documentation for the storage controller at
Dell.com/storagecontrollermanuals
.
If the drive is online, the green activity/fault indicator flashes as the drive is turned off. When the drive indicators are off, the drive is ready
for removal.
CAUTION:
To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation
supplied with your operating system.
CAUTION:
When a replacement hot swappable drive is installed and the system is powered on, the drive automatically begins to
rebuild. Ensure that the replacement drive is blank or contains data that you wish to overwrite. Any data on the replacement
drive is immediately lost after the drive is installed.
CAUTION:
Mixing drive carriers from previous generations of PowerEdge servers is not supported.
Steps
1
If required, lift the mid drive tray handles to 90 degrees upward.
2
Press the release tab on the drive tray and lift the drive carrier handle upward to disengage the drive from the backplane.
Installing and removing system components
83
Содержание PowerEdge R7425
Страница 9: ...Figure 1 Supported configuration PowerEdge R7425 system overview 9 ...
Страница 44: ...Option Description ...