The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
•
180 W/200 W CPUs are not supported.
•
Redundant power supply unit is required.
•
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
•
PCIe SSD is not supported.
•
Mid drive tray is not supported.
•
Rear storage devices or drives are not supported.
Thermal restrictions
Following table lists the configuration required for efficient cooling.
Table 30. Thermal restrictions support matrix
Configuration
number
Mid/rear
configuratio
n
Number
of
processor
s
Heatsink
Fan type
Shroud
DIMM
blank
Processor/
DIMM
blank
Fan
blank
180 W/200
W processor
155 W/170 W/120
W processor
1
(8 x 3.5 inch)
8 PCIe
1
2U
1U standard
performance
Four
standard
Standard
N/A
Yes
Yes
1
(8 x 3.5 inch)
8 PCIe
2
2U
1U standard
performance
Six
standard
Standard
N/A
N/A
N/A
2A
(24 x 2.5
inch)
8 PCIe
2
2U
1U standard
performance
Six
standard
Standard
N/A
N/A
N/A
2D
(32 x 2.5
inch)
Mid 4 x 2.5
inch + rear 4
x 2.5 inch
2
1U high
performance
1U standard
performance
Six high
performanc
e
N/A
Yes
N/A
N/A
3A
(12 x 3.5 inch) 8 PCIe
2
2U
1U standard
performance
Six
standard
Standard
N/A
N/A
N/A
3B
(18 x 3.5 inch)
Mid 4 x 3.5
inch + rear 2
x 3.5 inch
2
1U high
performance
1U standard
performance
Six high
performanc
e
N/A
Yes
N/A
N/A
4 (24 NVMe)
7 PCIe
2
2U
1U standard
performance
Six
standard
Standard
N/A
N/A
N/A
Ambient temperature limitations
The following table lists configurations that require ambient temperature less than 35°C.
NOTE:
The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess CPU throttling, which may
impact system performance.