6.4
“GRAPHICS” Menu
Access to the “GRAPHICS” menu allows the installer to view the following data recorded by the built-in
datalogger:
1.
Daily time-related data of PV system, battery, grid, residential load powers (Fig. 1).
2.
Weekly calculation, with daily partition, of energy produced by the PV generator, power sent to the
grid, power drawn from the grid, residential load.
3.
Yearly calculation, with monthly partition, of energy produced by the PV generator, power sent to the
grid, power drawn from the grid, residential load (Fig. 2).
Access to the different graphics is made by scrolling down by using the key associated with the selec-
tion of the type of graphics
4
1
5
3
2
Fig. 1
1. “GRAPHICS SELECTION” Key -
Press this key to select the different displays.
2. “SUN” Key
- Press this key to enable/disable the display of the associated value on the graphics area.
3. “ELECTRICITY GRID” Key
- Press this key to enable/disable the display of the associated value on the
graphics area.
4. “HOME” Key -
Press this key to enable/disable the display of the associated value on the graphics
area.
5. “BATTERY” Key
- Press this key to enable/disable the display of the associated value on the graphics
area.
Содержание DLS 300
Страница 4: ...4 Code 240 010 0001 DLS 300 450 600 Fig 01 ...
Страница 8: ...8 Code 240 010 0001 DLS 300 450 600 6 x Fig 05 ...
Страница 10: ...10 Code 240 010 0001 DLS 300 450 600 PV1 PV2 Fig 07 ...
Страница 11: ...DLS 300 450 600 11 Code 240 010 0001 PV Fig 08 ...
Страница 13: ...DLS 300 450 600 13 Code 240 010 0001 GEN N L PE PE N L PE GEN ON OFF REMOTE CONTROL OPTIONAL G Fig 10 ...
Страница 63: ...DLS 300 450 600 63 Code 240 010 0001 ...