Delem
V0208, 2.49
4.4.
Display codes
In the upper richt corner of the screen, a status code is shown that indicates the current status
of the control. Such a code can either be a status code or and error code.
The following table shows the possible status codes:
The following table shows the possible error codes:
(1) If this error occurs, reboot the control. If the error persists, contact your machine supplier.
S0
Stopped
Waiting for the operator to press start while pump start is
high
S1
Positioning
Not all axes are in position yet
S2
Wait for ST low
Waiting for STEP input falling edge
S3
Wait for EOS
Wait for EOS, generated by potentiometer or BR
S4
Wait for UDP
Wait for UDP, generated by potentiometer or STEP input
S5
Wait for STEP high
Waiting for STEP input rising edge
S6
Wait for end of retract Waiting for end of retract when STEP is already high.
S7
Wait for safe X
Waiting until X-axis is in safe area
E1..
Internal error (1)
E21
Power supply failure
E23
Encoder 1 error
E24
Encoder 2 error
E53
Invalid parameters
E56
No movement on X-axis
E57
No movement on A-axis
E58
No movement on G1-axis
E59
No movement on G2-axis
E94
Internal error (1)