Delem
V0208, 2.35
Due to the inertia of the system it is possible that the shear has a slight overshoot when it is
stopped at the computed value. The programmed ‘prestop’-value is subtracted from the
computed value, creating an EOS (end of stroke) output signal at an earlier moment than the
programmed moment.
2.6.
Force control parameters
Parameter 93
Main force enable
Range
: 0 - 1
Unit
: -
Default
: 0
Function
Enable or disable cutting force on the control.
0 = no control
1 = cutting force control enabled
Parameter 94
Cutting force factor
Range
: 0.1 - 999.9
Unit
: -
Default
: 1.0
Function
The (initially) calculated cutting force is multiplied with this factor.
Parameter 95
Main force reference table
Range
: -
Unit
: -
Default
: -
Function
Press ENTER to open a screen with the Cutting reference table. In this table, the relation
between cutting force and control output voltage can be programmed.