Delem
V0208, 2.19
If the X-axis position is smaller than X-limit, the X-axis moves at normal speed. If the X-axis
position is larger than X-limit, the X-axis moves at the speed, as programmed at ‘Limit
speed’(47).
Parameter 47
Limit speed
Range
: 0.0 - 100.0
Unit
: %
Default
: 50.0
Remark
Only if ‘Control type’ (19) is set to 3.
Function
Speed value at which the axis will move when the X-axis is outside the area defined by ‘X-
Limit(46). The speed is programmed as a percentage of the maximum speed.
This speed setting is also used when the input LSX is active.
Parameter 48
Acceleration, 0 to max.
Range
: 0 - 9999
Unit
: msec
Default
: 200
Remark
Only if ‘Control type’ (19) is set to 3.
Function
This is the nominal acceleration of the axis, used to control the axis from zero to maximum
speed when the axis must move to a new position. This parameter must be programmed as
the time in which the axis accelerates from zero to maximum speed.
Parameter 49
Deceleration, max. to 0
Range
: 0 - 999
Unit
: msec
Default
: 200
Remark