V0208, 2.26
Range
: 0.0 - 45.0
Unit
: degrees
Default
: 0.0
Remark
Only if the parameter ‘control enable’ (68) is set to 0.
Function
If there is no angle control, the (fixed) angle of the cutting blade can be programmed with this
parameter. This value will be used for stroke and force computations.
Parameter 71
Angle tolerance
Range
: 0.0 - 45.0
Unit
: degrees
Default
: 0.1
Function
Define the tolerance for the angle position. When the blade moves to a new angle position,
positioning stops when the angle is within the tolerance and the output A_IP becomes high.
Parameter 72
Angle prestop positive
Range
: 0 - 99
Unit
: AD value
Default
: 0
Function
Due to the inertia of the Angle system there can be some overshoot after the control output
has been switched off. To prevent such overshoot, the 'Angle prestop' can be programmed.
This parameter can be regarded as a programmable offset. The control will take this offset
into account when positioning the Angle. When the Angle system approaches the
programmed position, the control output is switched off at a certain distance (Angle prestop)
before the Angle has reached position. The ‘Angle prestop positive’ must be programmed for
Angle movement in the positive direction.