V0208, 2.21
Parameter 53
Positioning tolerance
Range
: 0.01 - 9999.99
Unit
: mm
Default
: 0.01
Remark
Only if ‘Control type’ (19) is set to 1 or 2.
Function
To set a range in which no new positioning takes place.
The axis will position to the new programmed position if the difference between the actual
position and the new position is greater than this tolerance. If the difference is smaller the axis
will stay at its actual position.
Parameter 54
AC brake enable
Range
: 0 - 1
Unit
: -
Default
: 0
Remark
Only if ‘Control type’ (19) is set to 1 or 2.
Function
Enable the brake output ‘BRK’. This can be used to control an AC motor with brake.
0 = no brake signal
1 = enable brake signal
If this signal is used, make sure to map the brake signal to an available digital output. The
brake signal is ‘low-active’: during positioning the signal is high, it will become low when the
brake must be applied.
Parameter 55
Brake delay
Range
: 0 - 9999
Unit
: msec
Default
: 0
Remark
Only if ‘Control type’ (19) is set to 1 or 2 and ‘AC Brake enable’ to 1.
Function
Delay time before AC brake is activated. The delay starts when the speed is set to 0.