Delem
V0208, 2.9
When this parameter is set to 1 (default value), all operation modes are available for the
operator.
When set to 0, the operation modes “Programming” and “Program selection” are not available
for the operator. The other modes will remain available. The tabs of these remaining modes
are aligned to the left in the Navigation bar.
Parameter 16
Enable CY
Range
: 0 - 1
Unit
: -
Default
: 1
Function
CY indicates the step repetition parameter. When CY is enabled, this parameter is activated
and can be programmed in Programming / auto mode.
0 = CY not enabled, program step repetition is not possible
1 = CY enabled, program step repetitions can be programmed.
Parameter 17
Number of FD functions
Range
: 0 - 4
Unit
: -
Default
: 0
Function
Program the number of available function outputs. These outputs are available for general
purposes. The values of these function outputs can be programmed by the operator.
If this parameter is programmed larger than 0, the parameter ‘Default value FD functions’
appears.
Parameter 18
Default FD functions
Range
: 0000 - 1111
Unit
: -
Default
: 0000
Function
Program a default value for the function outputs. This value must be programmed as a binary
number, in which each digit represents a digital function output.
This parameter only appears when the parameter ‘Number of FD functions’ is programmed
larger than 0.