Delem
V1101, 3.24a
Parameter FM:
Force Middle
Range
: 0 - 32000
Default
:
___
Units
:
kN
Pressure valve calibration enhancement
When the relation betwee the output deflection and the pressure is linear then you only have to
program force max. and force min. In case the relation between the output deflection and the
pressure is not linear you can program force middle.
The default value for this middle parameter is ‘___’, meaning that this parameter is not active.