Delem
V1101, 3.12
Parameter 12:
Max. Parallelism
Range
:
0.00-50.00
Default
:
2.00
Units
:
mm
Function
Total maximum allowed parallelism of the beam.
Description
The parallelism is the difference between the left hand cylinder (Y1) and the right hand cylinder
(Y2). For the controls there are two parameters that influence the beam parallelism:
1. Parallelism
programmable under the programming parameters. This value has effect over
the entire stroke of the beam.
2. Parallelism
programmable
in data preparation, data editing and manual mode. This value is
taken into account when the beam reaches the clamping point and stays active until the
opening command (
↑
) becomes active.
The total parallelism is the sum of the values described under 1 and 2. When in automatic mode
a total parallelism that is greater than the max. parallelism is detected the control goes to stop
and the following warning is displayed on the screen:
** Parallelism > max. parallelism **
Содержание DA-65
Страница 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Страница 17: ...Delem V1101 1 6...
Страница 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Страница 67: ...Delem V1101 3 28 Parameter 28 Not used...
Страница 68: ...Delem V1101 3 29 Parameter 29 Not used...
Страница 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Страница 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Страница 89: ...Delem V1101 3 53 Parameter 53 Not used...
Страница 94: ...Delem V1101 3 58 Parameter 58 Not used...
Страница 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Страница 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Страница 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Страница 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Страница 239: ......