Delem
V0303, 5.28
Parameter 130:
Safety distance
Range
: 0.00 - 999999.00
Default
:
50
Units
:
mm
Remark:
only for X/X1 axis, not for X2 axis
Function
To program a safety zone for the backgauge, where the backgauge will move with low speed.
Description
Sometimes it is required that the backgauge moves with low speed when it is within a small
distance from the die. This depends on local regulations. With this parameter, a safety distance is
programmed. When the backgauge moves within this distance from the die, the backgauge will
move with a low speed. This safety distance is related to the limit of the safety zone of the die (it
is not an X-position!).
Safety
distance
X safe
The maximum allowed speed within this area can be programmed at parameter 131, Safety
speed.
For an X2 axis this parameter is not available: the safety distance programmed at the X/X1 axis
is also valid for the X2 axis.
Содержание DA-65
Страница 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Страница 17: ...Delem V1101 1 6...
Страница 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Страница 67: ...Delem V1101 3 28 Parameter 28 Not used...
Страница 68: ...Delem V1101 3 29 Parameter 29 Not used...
Страница 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Страница 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Страница 89: ...Delem V1101 3 53 Parameter 53 Not used...
Страница 94: ...Delem V1101 3 58 Parameter 58 Not used...
Страница 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Страница 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Страница 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Страница 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Страница 239: ......