The point at which the optional mute output becomes active can also be shifted with an offset.
This offset does not shift the computed braking point. Just like the distance between the two
muting points this offset can only be changed by Delem on request. The default setting is 0.
Clamping (pinching) point output. This output becomes active when the
beam reaches the clamping (pinching) point and stays active as long as the
beam is below the clamping point.
Lower dead point output. This output becomes active at the end position of
the press beam. This output is active during Y-axis status 4.