Delem
V0802, 4.5
4.3
R-axis specific parameters
The following R-axis specific parameters are explained:
•
backgauge-die collision detection with R-axes;
•
automatic R-axis adjustment.
Backgauge-against-die collision detection
When you have enabled a R-axis (also R1 and R2) then the collision detection for backgauge-
against-die is active. A collision can occur when the R-axis position is negative. This means that
the backgauge finger lower is than the die height.
There are three critical situations. For all these situations a necessary condition is that the
R-in
input has to be active to be able to move the X-axis into the safety zone!
•
The X-axis has to move into the V-die safety zone. The R-axis will first move to a positive
position before the X-axis moves to the programmed position.
Figure 4.3.a
•
When the R-axis has to move from positive to negative, the X-axis must move out of the V-
die safety zone. The X-axis starts moving backwards but the R-axis does not move until the
X-axis is out of the safety zone.
Figure 4.3.b
Содержание DA-65
Страница 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Страница 17: ...Delem V1101 1 6...
Страница 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Страница 67: ...Delem V1101 3 28 Parameter 28 Not used...
Страница 68: ...Delem V1101 3 29 Parameter 29 Not used...
Страница 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Страница 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Страница 89: ...Delem V1101 3 53 Parameter 53 Not used...
Страница 94: ...Delem V1101 3 58 Parameter 58 Not used...
Страница 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Страница 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Страница 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Страница 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Страница 239: ......