Delem
V1101, 5.4
Parameter 12:
In position tolerance
Range
: 1.0 - 999.0
Default
:
1.0
Units
:
mm
Function
Zone in which the in-position output is active.
Description
Each axis has an in-position output. The parameter ‘In position tolerance’ defines the zone in
which this output is active. The output is active when:
Programmed value - actual value < +/- In position tolerance
Figure 5.2.a