![Delem DA-56 Скачать руководство пользователя страница 119](http://html1.mh-extra.com/html/delem/da-56/da-56_reference-manual_2465865119.webp)
Delem
V0505, 9.5
9.c
In this window the corrections of all bends are shown. You can browse through all corrections
and change them as you see fit. If a correction for
α
1 is entered then this value is copied to the
correction for
α
2. Different corrections for
α
2 can be entered in the field itself.
The columns 'measured
α
1/2' are present if they are enabled through the parameter 'angle cor-
rection computation' in the programming constants.
In the columns 'measured
α
1/2' the real, measured angle of the completed bend can be entered.
On entry of this measured angle, the control will automatically compute a necessary correction
to reach the programmed angle. If there is already a correction present, the control will adjust
this correction to account for the latest discrepancy.
The column ‘Stored correction’ is only available when the Angle correction database has been
activated. When activated, the column ‘Stored correction’ shows for each bend the correction
value that is present in the database. A blank entry in this column means the database does not
have a correction value for this type of bend. When a new correction is entered, it will be cop-
ied to the database automatically.
The markers ‘>’ indicate bends that have the same value.
The function key ‘all from stored’ serves to copy corrections in the database to the current pro-
gram: corrections in all bends are adjusted according to database values.