V0505, 9.4
ing corrections
If a correction is entered, it will be stored in the database. At each next bend with the same
properties, this same correction will be offered.
See the chapter ‘Program constants’ for more information on the angle correction database.
Corr X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cx =
Corrections on X-axis positions (Cx) in this bending. In case bend allowance is activated
(see PROGRAM CONSTANTS) and a program has been entered in data preparation, the
X-axes correction values are the result of bend allowance calculation. The corrections
will be saved in the active bending program.
The X-axis correction should be entered as following examples indicate:
1) Programmed value of 200 millimeters.
Measured value of 202 millimeters.
Then it is required to program Corr.x with -2
2) Programmed value of 200 millimeters.
Measured value of 198 millimeters.
Then it is required to program Corr.x with +2
Stock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ST =
The stock counter is incremented or decremented after each end of a program cycle.
G-Corr
α
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G
α
=
General correction of the angle, valid for each bend of the program. The value should be
programmed in the same manner as for the correction per bend.
G-Corr X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gx =
General correction of the X-axis position, valid for each bend of the program. The value
should be programmed in the same manner as for the correction per bend.
•
Corrections
Angle corrections can be edited in a separate window. This window can be activated by press-
ing the function key ‘all corr.’ in the main screen. The following window appears: