5.4.2
Position of the appliance
Caution
When installing the appliance, comply with the IP21 protection rat
ing.
Caution
Do not install the thermodynamic water heater in premises ex
posed to gas, vapours or dust.
The appliance should not take in air containing solvents or ex
plosive substances.
The air taken in must in no circumstances be dusty.
Adequate thermal insulation in relation to adjacent living spaces
is recommended.
Temperature of the ambient air or of the air taken in by the heat
pump for optimum running: 10 to 35 °C.
Install the appliance in a dry, frost-free room at a minimum temperature
of 7 °C.
Install the appliance on a flat, solid surface.
Install the appliance on a base frame. The base frame must be able to
support the load sufficiently at all times.
Recommended positions
Fig.7
1
2
5
3
4
MW
-1
0
0
0
3
6
6
-1
1
Garage
Unheated room.
Enables recovery of the free energy released by your vehicle's engine when switched off af
ter use or by household appliances in operation.
2
Via outside air
Connection to the outside air may lead to overconsumption of electricity if the outside air
temperature falls outside the operating range.
Minimum distance to be observed for the ducts if intake and backflow are done on the same
façade: 700 mm.
Note
Risk of inconvenience in Eco operating mode.
3
Habitable room
Can obtain free heat from the garage.
4
Laundry room
Unheated room.
Enables the dehumidification of the room and recovery of the energy wasted by washing
machines and tumble dryers.
5 Installation
300026515 - v09 - 25072017
21
Содержание KALIKO TWH 200 E
Страница 4: ...11 2 1 Specific information 68 Contents 4 300026515 v09 25072017 ...
Страница 55: ...No Date Checks made Remarks By Signature 8 Maintenance 300026515 v09 25072017 55 ...
Страница 69: ...11 Appendix 300026515 v09 25072017 69 ...
Страница 70: ...11 Appendix 70 300026515 v09 25072017 ...