27 Non-return valve
28 Domestic cold water inlet
29 Pressure reducer
30 Safety unit
33 Domestic hot water sensor
50 Disconnector
51 Thermostatic valve
52 Differential valve (only with module fitted with a
three-speed pump)
57 Domestic hot water outlet
90 Anti-thermosiphon loop
5.6.3
Connecting to solar collectors (TWH 300 EH model)
Caution
Limit the domestic hot water temperature to 60 °C.
Fig.15
C003612-B
4 Pressure gauge
27 Non-return valve
28 Domestic cold water inlet
29 Pressure reducer
30 Safety unit
57 Domestic hot water outlet
61 Thermometer
79 Domestic hot water tank solar exchanger primary
outlet
80 Domestic hot water tank solar exchanger primary in
let
84 Stop valve with releasable non-return valve
85 Primary solar circuit pump
87 Safety valve calibrated to 6 bar
88 Solar expansion vessel
89 Heat-transporting fluid container
90 Anti-thermosiphon loop (= 10 x pipe diameter)
109 Domestic hot water thermostatic mixing valve
112a Solar sensor probe
112b Solar domestic hot water sensor
114 Primary solar circuit filling and draining device
126 Solar regulator
129 Insulation
130 Manual venting degasser
131 Solar collectors
132 Complete solar station with solar control system
5 Installation
300026515 - v09 - 25072017
29
Содержание KALIKO TWH 200 E
Страница 4: ...11 2 1 Specific information 68 Contents 4 300026515 v09 25072017 ...
Страница 55: ...No Date Checks made Remarks By Signature 8 Maintenance 300026515 v09 25072017 55 ...
Страница 69: ...11 Appendix 300026515 v09 25072017 69 ...
Страница 70: ...11 Appendix 70 300026515 v09 25072017 ...