8.3
Accessing the bottom inspection trap
Note
Have a new lip gasket and a new retainer ring on hand for the in
spection hatch.
1. Disconnect the power supply.
2. Drain the water heater.
3. Open a hot water tap.
4. Open the valve on the safety unit.
5. Move the appliance to the repair position (1).
6. Check the extent of scaling in the tank and on the exchanger.
Leave the limescale on the walls of the tank: it provides effective
protection against corrosion and enhances the water heater's insula
tion.
Remove limescale deposits from the bottom of the tank.
Remove limescale deposits from the exchanger to guarantee its per
formance.
7. Remount the unit.
Caution
Each time it is opened, the lip retainer ring unit must be
replaced to guarantee a tight seal. Place the positioning lug on the
gasket towards the outside of the water heater.
8. After reassembly, check the tightness of the lower flange.
Note
The screws for the inspection hatch must be tightened to 6 N·m
+1/-0. Use a torque wrench.
8.4
Maintenance form
Tab.14
No.
Date
Checks made
Remarks
By
Signature
Fig.51
85°
1
C
00
31
9
0-C
8 Maintenance
54
300026515 - v09 - 25072017
Содержание KALIKO TWH 200 E
Страница 4: ...11 2 1 Specific information 68 Contents 4 300026515 v09 25072017 ...
Страница 55: ...No Date Checks made Remarks By Signature 8 Maintenance 300026515 v09 25072017 55 ...
Страница 69: ...11 Appendix 300026515 v09 25072017 69 ...
Страница 70: ...11 Appendix 70 300026515 v09 25072017 ...