44
• Identifying the injectors
The table below shows where the injectors
can be found on your appliance, according to
the type of gas used.
The number is marked on each injector.
94
Example:
injector marking 94
•Gas settings
Operating voltage
:
220-240 V~ - 50 Hz
Total absorbed electric power:
- 2 induction zone model
3100 W
(1)
Hob dimensions:
- Width
600 mm
- Depth
518 mm
Weight:
11.4 kg
- Dimensions of unit:
- Width
549 mm
- Height
59 mm
- Depth
470 mm
(1)
The heating powers are only given by
way of indication. It will depend on the type
and shape of the cookware.
Subject to modification.
EN
2
2 // INSTALLING YOUR APPLIANCE
SR
GR
60 cm hob with 2 gas burners and 2 induction zones
94
137
SR
GR
62
88A
Appliance intended to be installed in:
Butane
Propane
Natural
Natural
FR ...............................cat : II2E+3+
Gas
Gas
CH - ES - IT - PT .......cat : II2H3+
G30
G31
G20
G25
CY - EE - PL ..............cat : II2H3B/P
LT ...............................cat : I2H
Hourly rate below:
28-30 mbar
37mbar
20 mbar
25 mbar
25 mbar at 15°C under 1013 mbar
H
IGH SPEED BURNER
Marking on injector
88A
88A
137
137
Nominal heat release rate
(kW)
3.15
3.15
3.10
3.10
Reduced heat release rate
(kW)
0.830
0.870
0.870
Hourly rate
(g/h)
229
225
Hourly rate
(l/h)
295
343
S
EMI-FAST BURNER
Marking on injector
62
62
94
94
Nominal heat release rate
(kW)
1.50
1.50
1.50
1.50
Reduced heat release rate
(kW)
0.620
0.615
0.615
Hourly rate
(g/h)
109
107
Hourly rate
(l/h)
143
166
60
CM
H
OB WITH
2
GAS BURNERS
Total heat release rate
(kW)
4.60
4.60
4.60
4.60
Maximum rate
(g/h)
334
328
(l/h)
438
509
FR-CH
ES-IT
PT
FR-CH
ES-IT
PT
FR-CH
ES-IT
PT-CY
EE - PL
LT
FR