S07 X
Speed-Ports 0-7: there is a space between command and value
Range: 1 - 1G, 2 - 2G
Format: Hexadecimal
S8F X
Speed-Ports 8-15: there is a space between command and value
Range: 1 - 1G, 2 - 2G
Format: Hexadecimal
AM0 X
Address Mask 0 Bit Check: there is a space between command and value
Range: 1 - ENABLE, 0 - DISABLE
Format: Hexadecimal
LUM X
Look Up Mask: there is a space between command and value
Range: 0-3
Format: Hexadecimal
EDT X
E_D_TOV setting: there is a space between command and value
Range: 1 - 0x1F40 (1 - 8000ms)
Format: Hexadecimal
END\R\N
Command terminator. The end of line sequence is \r\n, ASCII codes 13 10.