background image

Printed in USA 

 

 

 

 

 

10/06

 

P/N 129465 

Hinge Wing Safety Interlock Switches

SI-HG63 Series Safety Interlock Switches Attached to a Load-Bearing Hinge

Models

Features

•  Safety switch is integrated into a highly robust PBT housing and screwed onto the 

fine-cast stainless steel hinge.

•  Safety switching point is repositionable.
•  Right-hinge, left-hinge, and right-angle hinge models available; switches can also be 

converted to operate from the opposite side.

•  A non-switching blank hinge is also available (see page 7).
•  Switch components are protected from mechanical impact, for superior performance 

to actuator-activated safety switches; rated IEC IP67.

•  Hinge operates to a full 270° range of motion; safety switching point (guard-closed 

position) is adjustable over the full 0–270°operating range.

•  Hinge can support an axial and radial load of 1200 N (120 Kg).
•  When properly interfaced or used with an appropriate controller, two 

SI-HG63

 

switches on an individual gate or guard can achieve safety category 4, per 

ISO 13849-1 (EN 954-1).

•  Typical applications include: 

– Hinged covers and guards to machines 

– Hinged doors and gates in safety fencing systems 

– Modular aluminum framing

*NOTE: Terminals 33 and 34 are non-safety.

Model

Housing Style/

QD Connection

Contact Configuration* 

(Gate Closed State)

Contact Configuration* 

(Gate Open State)

Switching 

Diagram

SI-HG63FQDR

Inline QD

With QD facing 
down, switch is 

mounted on right 

side of hinge

33

21

11

rd/bu

gn

rd

rd/bu

rd

34

22

12

rd/bk

rd/ye

rd/wh

rd/bk

rd/ye

rd/wh

33

21

11

gn

34

22

12

33

21

11

rd/bu

gn

rd

rd/bu

rd

34

22

12

rd/bk

rd/ye

rd/wh

rd/bk

rd/ye

rd/wh

33

21

11

gn

34

22

12

Contacts:   Open   Closed   Transition

SI-HG63FQDL

Inline QD

With QD facing 
down, switch is 

mounted on left 

side of hinge

SI-HG63FQDRR

Right-Angle QD

With switch body 

down, switch is 

mounted on right 

side of hinge

Safety

Operating

Angle

Non-Safety

Operating

Angle

Model SI-HG63FQDR 

shown

Содержание SI-HG63FQDR

Страница 1: ...operly interfaced or used with an appropriate controller two SI HG63 switches on an individual gate or guard can achieve safety category 4 per ISO 13849 1 EN 954 1 Typical applications include Hinged covers and guards to machines Hinged doors and gates in safety fencing systems Modular aluminum framing NOTE Terminals 33 and 34 are non safety Model Housing Style QD Connection Contact Configuration ...

Страница 2: ... satisfied Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed U S Regulations Applicable to Use of Banner Safety Switches OSHA Code of Federal Regulations Title 29 Parts 1900 to 1910 Available from Superintendent of Documents Government Printing Office P O Box 371954 Pittsburgh PA 15250 7954 Tel 202 512 1800 U S Stan...

Страница 3: ...an end stop The operating angle of the switch must be limited by outer end stops WARNING It must not be possible for personnel to reach any hazard point through an opened guard or any opening before hazardous machine motion has completely stopped Please reference OSHA CFR 1910 217 and ANSI B11 standards see page 2 for information on determining safety distances and safe opening sizes for your guar...

Страница 4: ...in the screws for later reuse 2 Insert a flat blade screwdriver between the hinge housing and the plastic plug to gently pry the plastic plugs out Retain the plastic plugs for later reuse Figure 3b 3 Remove the hinge portion from the switch Lift the red plastic washer from the switch Discard the plastic washer it cannot be reused Figures 3c and 3d 4 Align the switch cylinder arrow with mark A on t...

Страница 5: ...Hinge Switches SI HG63 Series P N 129465 Banner Engineering Corp Minneapolis MN U S A www bannerengineering com Tel 763 544 3164 h Figure 3 Relocating the switch point setting a b c d e g f SW8 ...

Страница 6: ...age Signs of tampering or defeat to the switch or to the wiring interface to the machine A designated person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure Repairs Do not attempt any repairs to the switch It contains no field replaceable components Return the switch to the factory for warranty repair or replacement If it becomes ne...

Страница 7: ... Blow Recommended external fusing or overload protection Force Exerted by Guard per Switch Axial and Radial 1200 N 264 lbf max Operating Range 0 to 270 Wire Connections 6 pin Micro style quick disconnect QD fitting Cordsets are ordered separately see page 8 Construction Hinge X22CrNi 17 Switch PBT Environmental Rating NEMA 4 IEC IP67 acc IEC EN60529 Operating Conditions Temperature 25 to 70 C 13 t...

Страница 8: ... returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or implied Accessories Blank Hinge Model Description Dimensions SI HG63A Blank hinge same mechanical specifications as SI HG63 Series hinge switches but without the safety switch componen...

Отзывы: