Figure 9. Configuration Menu
Note:
You can always return to the Main Menu from any sub-menu by entering a
succession of “q” and “<return>”. This feature allows the user a fast and
easy way to get back to the top menu from any sub-menu.
4.2.5.1 Domain ID Sub-menu
This configuration sub menu allows you to configure the lower 2 bits of the Domain
ID. A unique Domain ID identifies each switch in a multi-switch fabric. This screen is
straightforward and is shown in Figure 10. The user entry “1” is shown in bold.
Figure 10. Domain ID
4.2.5.2 Master Switch Selection Sub-menu
This configuration sub menu allows you to configure the switch as the master switch,
or not. This screen is straightforward and is shown in Figure 11. The user entry “1” is
shown in bold.
Figure 11. Master Switch Selection
*** CONFIGURATION MENU ***
Switch...0x100000a0 550005d7 Mstr Switch...0x00000000 00000000
Board Rev: 1, S/N: 14934, Control #: 0, Source: Flash
1 Domain ID : 0x1
2 Master Sw : OFF
3 WKA Config
4 Global Settings
5 IMPLICIT Name Server Config
6 Ethernet Settings
7 Port Settings
8 Modify Routing Table
9 Download File
Type Selection & Press Enter to Continue('q' to quit)>
*** SET DOMAIN ID ***
Enter ID(0-3) ('q' to quit): 0x
1
*** MASTER SWITCH SELECTION ***
Enter Master(1-YES,0-NO)? ('q' to quit):
1