Built-In Grill Clearances
11
12"
FRONT
REAR
IGNITER
ROTIS
GRILL
GRILL
GRILL
IGNITER
GRILL
IGNITER
GRILL
GRILL
IGNITER
ROTIS
IGNITER
SMOKER
IGNITER
SMOKER
"
"
"
7/8"
7/8"
FIG. 03
IMPORTANT:
Gas fittings, regulator, and installer supplied shut-off valves must be easily accessible.
CLEARANCES TO COMBUSTIBLE CONSTRUCTION
Above and below the cooking surface, maintain a minimum of 12" from the sides and a minimum of
12" from the back to adjacent vertical combustible construction.
CLEARANCES TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 3" clearance from the back of the grill to non-combustible construction is required for
lid to fully open. A minimum of 8" clearance from both sides is required for the rotisserie motor and
skewer handle .The grill can be placed directly adjacent to non-combustible construction below the
cooking surface.
INSULATED JACKET
Do not build the grill under overhead unprotected combustible construction. If the grill is to be
placed into a combustible enclosure, an approved insulated jacket is necessary and is available from
your dealer. Use only the DCS insulated jacket which has specifically been designed and tested for this
purpose.