Troubleshooting
Setting this parameter to a non zero value will enable a Keep-Alive feature in the Unit. When the Unit is in
Client mode, it will send Keep-Alive messages to the server at the specified frequency when the
link between the client and server is idle. When the Unit is in Server mode, it will close the
connection if the link is idle for more than 3.5 times the Keep-Alive Frequency. The Telnet
modes work differently: the Server end sends Telnet NOPs, and the Client end times out.
[0=OFF, 1-32767 seconds]
25