Configuration
Monitor Data Port RX/TX (MR/MT)
Monitor data port: RX - Press ESC-ESC to quit.
MT
Monitor data port: RX TX - Press ESC-ESC to quit.
Stop port monitor
MR monitors data received on the network going out of the data port. MT monitors data coming into the
data port being sent out the network port. Both commands can be active at the same time. The data on the
screen will be tagged at [RX] or [TX] as it is displayed. Press the <Esc> key twice to exit the command.
Monitor Data Port in HEX (MRH/MTH)
MRH and MTH work the same as MR and MT except the data are displayed in HEX.
Show RS232 (SR)
Data Port RS232: RTS(8)-HI CTS(7)-HI DTR(3)-HI DCD(2)-HI DSR(1)-HI
This command displays the current state of the data port RS232 control leads.
Round Trip Delay (RTD)
Measure Round Trip Delay...
Round Trip Delay is 2 ms.
This command measures the round trip delay between the local and remote AVA-Es. The delay is rounded
to the nearest 1ms and cannot be 0. Press the <Esc> key to exit the command.
21