DB Electronics DSW-100 Series Скачать руководство пользователя страница 21

35

34

   7.2   

Standard POS serial port protocol

x46,0x0d,0x0a

      Ex3.  When NET WEIGHT is underload.  (When the weight is less 

than -2 divisions, and the negative weight mask function spec06.

bit3,2=00,01 has been set)

                 The data format is  0x30,0x20,0x20,0x20,0x20,0x20,0x55,0x

46,0x0d,0x0a

7.1.6 Get weight data by command:

7.1.6.1.  Get  standard  weight  data  command  1  (a  simple 

command to get weight data using single characters)

SPEC SETUP:   SPEC 01=X100,Baud=9600bit/s

SPEC 02=010X,Simple command data output

SPEC 20=XX00,Data=8bit,Stop=1bit,No parity

Input command: Use single character (byte) command: A(41H) or 

a(61H)

Output message: Output 5 Byte (ASCII Code) weight data, no 

decimal point, high digits in front, no sign.

For example: weight = 1.235kg then: 30H,31H,32H,33H,35H

Note: 1. The above setting value ‘X’ is a bit that does not affect 

this working mode, (0/1 are both possible)

         2. When using this command to obtain weight data, the output 

data format does not include the weight unit, and after the weight 

unit is converted, the value output will not change, only the value 

of the weight unit set during calibration.

7.1.6.2. Get standard weight data command 2 (Use standard 

commands to get weight data)

SPEC SETUP: SPEC 01=X100, Baud=9600bit/s

SPEC 02=000X, command mode data output

SPEC 20=XX00, Data=8bit, Stop=1bit, no parity

Input command: 3-byte command: 02H,0DH,0AH

Output message: Output 24 Byte (ASCII Code) weight data, 

including weight unit, stability indicator, decimal point, sign,

The high digits come first.

Message format: 06 20 67 30 0D 47 30 30 31 2E 30 30 30 0D 54 30 31 

30 2E 30 30 30 0D 0A

Note: 1. The above setting value ‘X’ is a bit that does not affect 

this working mode, (0/1 are both possible)

         2. When using this command method to obtain weight data, 

the output data format includes the weight unit, and after the 

weight unit is converted, the numerical output will be based on 

the unit value of the displayed weight.

DSW-100 FOR POS/ECR INTERFACE & Protocol

7.2.1 POS/ECR Interface

        DSW-100 POS/ECR Version can interface with most POS/ECRs 

by selecting 

TYPE 0 to TYPE 7.   (TYPE 0, 2, 4, 5, 6, 7)

7.2.2 POS/ECR (Type Selection) 

      (1) POS/ ECR-Type TYPE selected in making sure the power 

has been turned off.Press and hold the tare key before turning on 

the power.

      At this point, the electronic scale will display the currently 

selected POS/ECR type, which will be displayed on the monitor 

as "P.OS.T. 0".

Indicates that you have selected (POS/ ECR-type 0). You can press 

the tare key again to select another POS/ECR.

Press zero to save the Settings and return to weighing mode.

(2) If you want to change POS/ECR type then press 'TARE' key to 

change POS/ECR Type.

(3) To save current POS/ECR type, press the [ ZERO ] key.

SPECIAL DATA TYPE

7.2

7. SERIAL AND USB

7. SERIAL AND USB

7.3 Standard serial port protocol

Description / RS-232C Serial

DISPLAY

MENU

“t   00”

POS/ECR 
-TYPE 0
POS/ECR 
-TYPE 2
POS/ECR 
-TYPE 4
POS/ECR 
-TYPE 5
POS/ECR 
-TYPE 6
POS/ECR 
-TYPE 7

“t   02”

“t   04”

“t   05”

“t   06”

“t   07”

Most P.O.S, ECRs and Some TEC P.O.S System / 
9600 Baud rate, 7 Data bit, Even Parity, 1Stop bit

CRS, NCR2170 and Many other ECRs,Most  P.O.S  Software  
/  9600  Baud rate, 7 Data bit, Even Parity, 1Stop bit.

DELTA cash register protocol Communication type / 
9600 Baud rate, 8 Data bit, Non Parity, 1Stop bit.

SAMSUNG ER-670, ER-5100, SPS-520, Most P.O.S 
Software / 9600 Baud rate, 8 Data bit, Non Parity, 1Stop bit.

SHARP ER-Axxx, ER-A450T, New SANYO ECRs,Using  RS-
232  and  others /9600 Baud rate, 7 Data bit,  Even Parity, 1Stop bit

NCI General, SAMSUNG SPS-300, ER-900, Most P.O.S 
Software  /  9600  Baud rate, 7 Data bit, Even Parity, 1Stop bit.

Содержание DSW-100 Series

Страница 1: ...DSW 100 SHANGHAI DIGITAL BALANCE ELECTRONIC CO LTD version1 4 2020 12...

Страница 2: ...eatures through this manual DSW 100 has weighing and counting functions Backlit display with automatic energy saving mode In addition the brightness of the backlight and the auto off time are set by t...

Страница 3: ...ons Make sure that one scale uses a matching power outlet Do not insert metal or flammable objects at the interface to avoid damage to the machine or fire If the scale falls please turn off the switch...

Страница 4: ...th and wipe with a detergent Do not use thinner or other volatile solvents In order to ensure the normal use of the scale before starting the operation every day adjust the level and lock the foot nut...

Страница 5: ...hen the weight is locked HOLD the indicator lights It is the operation confirmation and data save button in the setting mode and the zero operation button in the weighing mode Host power switch exit s...

Страница 6: ...o exit the field check and enter the weighing mode 2 When the battery capacity indicator shows only one frame it means that the internal battery voltage is too low please replace the battery Please us...

Страница 7: ...the heavy object which shows 0 500kg Method 2 Unplug the AC power and shut down Click REZERO again to reset to zero ON OFF Note When charging is not required unplug the AC power Note 1 If the placed w...

Страница 8: ...pressing the tare key 2 The peeling range can be modified by SPEC 04 BIT 0 to select the allowed peeling range of 50 FS or 100 FS TARE 1 Ensure that the scale is in a stable state 2 Press and hold th...

Страница 9: ...ase the number of objects placed on the weighing pan Make sure the scale is stable 1 Press and hold the key for 5 seconds to enter the weighing mode If there is already weight on the weighing pan when...

Страница 10: ...the weighing pan such as 0 545kg Click the key it is displayed as 1 202lb click the key again it is displayed as 19 22oz the third click the key it is displayed as 545g the fourth time it is restored...

Страница 11: ...quick operations you need to hold down the REZERO key for a long time while pressing other keys 2 Before restoring the factory SPEC settings you need to open the calibration switch at the bottom of t...

Страница 12: ...rmat setting 00 Generalcommandresponsemethod 10 POS ECR communication method 01 Simplecommand A responsemethod 11 Continuousweightdataoutputmethod The default is 1000 the RS 232 USB communication mode...

Страница 13: ...cremental key and increases 1 from right to left After the operation click REZERO to save and enter the next item click ON OFF to exit without saving REZERO ON OFF 3 5 System function definition SPEC...

Страница 14: ...interval onlyforfixmode1 SPEC NO 11 SPEC NO 12 000 No decimal point 100 Four decimal places 00 0000 001 One decimal 00000 0 101 Five decimal places 0 00000 010 Two decimal places 0000 00 011 Three dec...

Страница 15: ...BIT 0 Display items for measuring voltage The default is 0000 SPEC NO 19 BIT 3 BIT 2 BIT 1 BIT 0 Do not use Note 1 Set the unused setting bits to 0 2 FS is full weighing value 3 The system function i...

Страница 16: ...witch SPAN SW must be on 4 2 Full scale rate correction Click REZERO button to save Click the switch below the scale body to open the calibration Put a heavy object on the weighing platform such as 10...

Страница 17: ...F key to directly exit the calibration mode and return to the weighing mode 2 The calibration switch SPAN SW must be turned on 3 Calculation of the new standard rate Actual weight W1 10 00kg Display w...

Страница 18: ...storing the modified values of BIT 3 Spec 10 BIT 0 Spec 09 Spec 11 Spec 12 Spec 13 Coding Coding SPEC00 SPEC01 SPEC02 SPEC03 SPEC20 SPEC21 Defaults Defaults 1100 0100 0100 1011 1100 0000 SPEC04 SPEC05...

Страница 19: ...ata 8bit Stop 1bit no parity SPEC 21 0XXX The output data is synchronized with the display data when there is weight unit conversion SPEC 21 1XXX The output data is not synchronized with the display d...

Страница 20: ...H LSB 0DH Note 1 All characters are printed in ASCII code Contains only the numerical symbol the net weight value and the ending character CR 0DH with the higher value coming first When the value is n...

Страница 21: ...are both possible 2 When using this command method to obtain weight data the output data format includes the weight unit and after the weight unit is converted the numerical output will be based on t...

Страница 22: ...N 4EH 60lb E 45H 6kg C 43H 10kg I 49H 15kg A 41H 20kg J 4AH 25kg P 50H 30kg B 42H 60kg O 4FH 7 SERIAL AND USB 7 3 Standard serial port protocol 7 2 4 TYPE 2 INTERFACE Discontinual RS 232C Interface S...

Страница 23: ...ys 1 0 0 0 0 0 0 B2 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 7 SERIAL AND USB 7 3 Standard serial port protocol ii Simplified Status Codes iii Serial Communication 9600 Baud rate 7 Data bit Eve...

Страница 24: ...z 1000oz X XXX X XXX XX XXX XX XXX XXX X XXX X XXX X XXX X XX XXX XXXX X XX XX XX XX XX XX XX XX XX XX XX XX 5kg 6kg 10kg 20kg 30kg 7 SERIAL AND USB 7 3 Standard serial port protocol 7 2 7 TYPE 6 INTE...

Страница 25: ...0x2E This type efficiency NET WEIGHT data length is 7 digital With decimal point S FIX WORD 0x2B Weight is positive valve 0x2d Weight is minus value D 0x44 RS_CR 0x0d RS_LF 0xoa 3 Serial Communication...

Страница 26: ...Add No 788 Songxiu Road Qingpu Industrial Park Shanghai 201703 P R China Tel 0086 21 59757333 Tax 0086 21 69758587 Http www dbscale com cn version1 2 2020 6 version1 3 2020 8 version1 4 2020 12...

Отзывы: