17
16
3.3
Customer function SPEC definition
SPEC NO.00
SPEC NO.03
SPEC NO.01
00:10 seconds
00:Weight display
lock(HOLD)
000: Port closed
100: 9600
00:10 seconds
【BIT 3/BIT 2】Backlight auto-off time setting
【BIT 3】Allow "comma" as decimal point
【BIT 3】Backlight function settings
【BIT 0】Automatic shutdown time setting (after 3 minutes of no operation)
【BIT 1/BIT 0】[TARE/ ↑ ] key function setting (in weighing mode) after the clock)
01:20 seconds
01: Gross weight/
n e t w e i g h t
switch
001: 1200
101:19200
0:Allow
0:Allow
0:Allow
0:Allow
10:30 seconds
1 0 : F u n c t i o n
key for counting
mode
010: 2400
110:38400
1:Forbid
1:Forbid
1:Forbid
1:Forbid
10:30 seconds
11:Do not close
1 1 : T a r e
operation key
only
011: 4800
111: 57600
【BIT 1】Allow automatic entry into power saving mode
【BIT 2】Weight unit conversion (kg/LB) [UNIT / ← ]
【BIT 2/BIT 1/BIT 0】RS-232 baud rate setting
Note:
(1) When the backlight brightness is set to "0", the backlight will not
automatically turn on;
(2) 60 seconds to enter power saving mode
*The default is 1100, the backlight does not turn off automatically; allow to
enter the power saving mode; no automatic shutdown
*The default is 1011, it is forbidden to use a comma as the decimal point; it
is allowed to use the [ ← ] key to switch the weight unit; [ ↑ ] key is only the
tare operation key in the weighing mode
*The default is 0100, the backlight function is turned on; the baud rate of
RS-232 is 9600
3. EDIT SETTINGS
3. EDIT SETTINGS
3.3 Customer function SPEC definition
3.3 Customer function definition
0:Allow
0:Standard
1:Forbid
1:Special
SPEC NO.02
【BIT 3/BIT 2】RS-232/USB communication mode setting
【BIT 1】Allow RS-232 port data output when the weight is unstable
【BIT 0】RS-232 port data output format setting
00:General command response method
10: POS/ECR communication method
01: Simple command (A) response method
11: Continuous weight data output method
*The default is 1000, the RS-232/USB communication mode is set to POS/
ECR communication mode; the RS-232 port data output is allowed when the
weight is unstable; the standard RS-232 port data format is output
00: 8 data bits,
NO Parity
01: 7 data bits,
Even Parity
00: Special format 1: Data format protocol 1
10: 7 data bits,
Odd Parity
01: Special format 2: Data format protocol 2
11: 7 data bits,
Mark Parity
SPEC NO.20
【BIT 1/BIT 0】RS-232 SERIES DATA BIT AND PARITY VALUES
【BIT 3/BIT 2】RS-232 SPECIAL DATA MODE SELECT
10: Special format 3: TOLEDO MODE protocol 11: Special format 4: DIGI MODE protocol
*The default is 0000, the special data format protocol 1; RS-232
communication protocol uses 8 data bits, no check
SPEC NO.21
0 0 0 : P O S / E C R
TYPE-0
Most P.O.S, ECRs
and Some TEC
P.O.S System
1 0 0 : P O S / E C R
TYPE-4
CRS, NCR2170
and Many other
ECRs, Most P.O.S
1 1 0 : P O S / E C R
TYPE-6
SAMSUNG ER-670,
ER-5100, SPS-520,
Most P.O.S
1 1 1 : P O S / E C R
TYPE-7
D E L T A c a s h
register protocol
1 0 1 : P O S / E C R
TYPE-5
N C I G e n e r a l ,
SAMSUNG SPS-300,
ER-900, Most P.O.S
0 0 1 : P O S / E C R
TYPE-1
NOT USE
0 1 0 : P O S / E C R
TYPE-2
SHARP ER-Axxx,
ER-A450T, New
SANYO ECRs
0 1 1 : P O S / E C R
TYPE-3
NOT USE
[BIT 2/BIT 1/BIT 0] POS/ECR communication protocol selection
(can be switched by pressing [Tare key] when turning on)
0: Synchronize with the displayed weight unit 1: Use the original set weight unit
【BIT 3】Data (serial port) output weight unit selection
Note:
1. SPEC21 command "D, CR, LF" response mode
2. For the PROTOCOL (interface protocol) of POS/ECR TYPE-0 ~ 7 in
SPEC21, please refer to the following description of this article (POS/ECR
INTERFACE) 9600 Baud rate, 7 Data bit, Even Parity, 1 Stop bit
(TYPE-6: 9600 Baud rate, 8 Data bit, None Parity, 1 Stop bit)
3. Set the unused setting bits to "0"