background image

17

16

  3.3 

 Customer function SPEC definition

SPEC NO.00

SPEC NO.03

SPEC NO.01

00:10 seconds

00:Weight display 

lock(HOLD)

000: Port closed

100: 9600

00:10 seconds

【BIT 3/BIT 2】Backlight auto-off time setting

【BIT 3】Allow "comma" as decimal point

【BIT 3】Backlight function settings

【BIT 0】Automatic shutdown time setting (after 3 minutes of no operation)

【BIT 1/BIT 0】[TARE/ ↑ ] key function setting (in weighing mode) after the clock)

01:20 seconds

01: Gross weight/

n e t   w e i g h t 

switch

001: 1200

101:19200

0:Allow

0:Allow

0:Allow

0:Allow

10:30 seconds

1 0 :   F u n c t i o n 

key for counting 

mode

010: 2400

110:38400

1:Forbid

1:Forbid

1:Forbid

1:Forbid

10:30 seconds

11:Do not close

1 1 :   T a r e 

operation  key 

only

011: 4800

111: 57600

【BIT 1】Allow automatic entry into power saving mode

【BIT 2】Weight unit conversion (kg/LB) [UNIT / ← ]

【BIT 2/BIT 1/BIT 0】RS-232 baud rate setting

Note: 
(1) When the backlight brightness is set to "0", the backlight will not 
automatically turn on;
(2) 60 seconds to enter power saving mode

*The default is 1100, the backlight does not turn off automatically; allow to 
enter the power saving mode; no automatic shutdown

*The default is 1011, it is forbidden to use a comma as the decimal point; it 
is allowed to use the [ ← ] key to switch the weight unit; [ ↑ ] key is only the 
tare operation key in the weighing mode

*The default is 0100, the backlight function is turned on; the baud rate of 
RS-232 is 9600

3. EDIT SETTINGS

3. EDIT SETTINGS

3.3 Customer function SPEC definition

3.3 Customer function definition

0:Allow

0:Standard

1:Forbid

1:Special

SPEC NO.02

【BIT 3/BIT 2】RS-232/USB communication mode setting

【BIT 1】Allow RS-232 port data output when the weight is unstable

【BIT 0】RS-232 port data output format setting

00:General command response method

10: POS/ECR communication method

01: Simple command (A) response method

11: Continuous weight data output method

*The default is 1000, the RS-232/USB communication mode is set to POS/
ECR communication mode; the RS-232 port data output is allowed when the 
weight is unstable; the standard RS-232 port data format is output

00:  8  data  bits, 

NO Parity

01:  7  data  bits, 

Even Parity

00: Special format 1: Data format protocol 1

10:  7  data  bits, 

Odd Parity

01: Special format 2: Data format protocol 2

11:  7 data bits, 

Mark Parity

SPEC NO.20

【BIT 1/BIT 0】RS-232 SERIES DATA BIT AND PARITY VALUES

【BIT 3/BIT 2】RS-232 SPECIAL DATA MODE SELECT

10: Special format 3: TOLEDO MODE protocol  11: Special format 4: DIGI MODE protocol 

*The default is 0000, the special data format protocol 1; RS-232 
communication protocol uses 8 data bits, no check

SPEC NO.21

0 0 0 :   P O S / E C R 

TYPE-0 

Most P.O.S, ECRs 

and  Some  TEC 

P.O.S System

1 0 0 :   P O S / E C R 

TYPE-4 

CRS,  NCR2170 

and Many other 

ECRs, Most P.O.S

1 1 0 :   P O S / E C R 

TYPE-6 

SAMSUNG ER-670, 

ER-5100, SPS-520, 

Most P.O.S 

1 1 1 :   P O S / E C R 

TYPE-7 

D E L T A   c a s h 

register protocol 

1 0 1 :   P O S / E C R 

TYPE-5 

N C I   G e n e r a l , 

SAMSUNG SPS-300, 

ER-900, Most P.O.S

0 0 1 :   P O S / E C R 

TYPE-1 

NOT USE

0 1 0 :   P O S / E C R 

TYPE-2 

SHARP ER-Axxx, 

ER-A450T,  New 

SANYO ECRs

0 1 1 :   P O S / E C R 

TYPE-3 

NOT USE

[BIT 2/BIT 1/BIT 0] POS/ECR communication protocol selection 

(can be switched by pressing [Tare key] when turning on)

0: Synchronize with the displayed weight unit 1: Use the original set weight unit

【BIT 3】Data (serial port) output weight unit selection

Note: 
1. SPEC21 command "D, CR, LF" response mode
2.  For  the  PROTOCOL  (interface  protocol)  of  POS/ECR  TYPE-0  ~  7  in 
SPEC21, please refer to the following description of this article (POS/ECR 
INTERFACE) 9600 Baud rate, 7 Data bit, Even Parity, 1 Stop bit
(TYPE-6: 9600 Baud rate, 8 Data bit, None Parity, 1 Stop bit)
3. Set the unused setting bits to "0"

Содержание DSW-100 Series

Страница 1: ...DSW 100 SHANGHAI DIGITAL BALANCE ELECTRONIC CO LTD version1 4 2020 12...

Страница 2: ...eatures through this manual DSW 100 has weighing and counting functions Backlit display with automatic energy saving mode In addition the brightness of the backlight and the auto off time are set by t...

Страница 3: ...ons Make sure that one scale uses a matching power outlet Do not insert metal or flammable objects at the interface to avoid damage to the machine or fire If the scale falls please turn off the switch...

Страница 4: ...th and wipe with a detergent Do not use thinner or other volatile solvents In order to ensure the normal use of the scale before starting the operation every day adjust the level and lock the foot nut...

Страница 5: ...hen the weight is locked HOLD the indicator lights It is the operation confirmation and data save button in the setting mode and the zero operation button in the weighing mode Host power switch exit s...

Страница 6: ...o exit the field check and enter the weighing mode 2 When the battery capacity indicator shows only one frame it means that the internal battery voltage is too low please replace the battery Please us...

Страница 7: ...the heavy object which shows 0 500kg Method 2 Unplug the AC power and shut down Click REZERO again to reset to zero ON OFF Note When charging is not required unplug the AC power Note 1 If the placed w...

Страница 8: ...pressing the tare key 2 The peeling range can be modified by SPEC 04 BIT 0 to select the allowed peeling range of 50 FS or 100 FS TARE 1 Ensure that the scale is in a stable state 2 Press and hold th...

Страница 9: ...ase the number of objects placed on the weighing pan Make sure the scale is stable 1 Press and hold the key for 5 seconds to enter the weighing mode If there is already weight on the weighing pan when...

Страница 10: ...the weighing pan such as 0 545kg Click the key it is displayed as 1 202lb click the key again it is displayed as 19 22oz the third click the key it is displayed as 545g the fourth time it is restored...

Страница 11: ...quick operations you need to hold down the REZERO key for a long time while pressing other keys 2 Before restoring the factory SPEC settings you need to open the calibration switch at the bottom of t...

Страница 12: ...rmat setting 00 Generalcommandresponsemethod 10 POS ECR communication method 01 Simplecommand A responsemethod 11 Continuousweightdataoutputmethod The default is 1000 the RS 232 USB communication mode...

Страница 13: ...cremental key and increases 1 from right to left After the operation click REZERO to save and enter the next item click ON OFF to exit without saving REZERO ON OFF 3 5 System function definition SPEC...

Страница 14: ...interval onlyforfixmode1 SPEC NO 11 SPEC NO 12 000 No decimal point 100 Four decimal places 00 0000 001 One decimal 00000 0 101 Five decimal places 0 00000 010 Two decimal places 0000 00 011 Three dec...

Страница 15: ...BIT 0 Display items for measuring voltage The default is 0000 SPEC NO 19 BIT 3 BIT 2 BIT 1 BIT 0 Do not use Note 1 Set the unused setting bits to 0 2 FS is full weighing value 3 The system function i...

Страница 16: ...witch SPAN SW must be on 4 2 Full scale rate correction Click REZERO button to save Click the switch below the scale body to open the calibration Put a heavy object on the weighing platform such as 10...

Страница 17: ...F key to directly exit the calibration mode and return to the weighing mode 2 The calibration switch SPAN SW must be turned on 3 Calculation of the new standard rate Actual weight W1 10 00kg Display w...

Страница 18: ...storing the modified values of BIT 3 Spec 10 BIT 0 Spec 09 Spec 11 Spec 12 Spec 13 Coding Coding SPEC00 SPEC01 SPEC02 SPEC03 SPEC20 SPEC21 Defaults Defaults 1100 0100 0100 1011 1100 0000 SPEC04 SPEC05...

Страница 19: ...ata 8bit Stop 1bit no parity SPEC 21 0XXX The output data is synchronized with the display data when there is weight unit conversion SPEC 21 1XXX The output data is not synchronized with the display d...

Страница 20: ...H LSB 0DH Note 1 All characters are printed in ASCII code Contains only the numerical symbol the net weight value and the ending character CR 0DH with the higher value coming first When the value is n...

Страница 21: ...are both possible 2 When using this command method to obtain weight data the output data format includes the weight unit and after the weight unit is converted the numerical output will be based on t...

Страница 22: ...N 4EH 60lb E 45H 6kg C 43H 10kg I 49H 15kg A 41H 20kg J 4AH 25kg P 50H 30kg B 42H 60kg O 4FH 7 SERIAL AND USB 7 3 Standard serial port protocol 7 2 4 TYPE 2 INTERFACE Discontinual RS 232C Interface S...

Страница 23: ...ys 1 0 0 0 0 0 0 B2 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 7 SERIAL AND USB 7 3 Standard serial port protocol ii Simplified Status Codes iii Serial Communication 9600 Baud rate 7 Data bit Eve...

Страница 24: ...z 1000oz X XXX X XXX XX XXX XX XXX XXX X XXX X XXX X XXX X XX XXX XXXX X XX XX XX XX XX XX XX XX XX XX XX XX 5kg 6kg 10kg 20kg 30kg 7 SERIAL AND USB 7 3 Standard serial port protocol 7 2 7 TYPE 6 INTE...

Страница 25: ...0x2E This type efficiency NET WEIGHT data length is 7 digital With decimal point S FIX WORD 0x2B Weight is positive valve 0x2d Weight is minus value D 0x44 RS_CR 0x0d RS_LF 0xoa 3 Serial Communication...

Страница 26: ...Add No 788 Songxiu Road Qingpu Industrial Park Shanghai 201703 P R China Tel 0086 21 59757333 Tax 0086 21 69758587 Http www dbscale com cn version1 2 2020 6 version1 3 2020 8 version1 4 2020 12...