23

22

*The default is 1001, the number of divisions allowed for overload display is 9d

*The default is 0000

*The default is 1111

*The default is 1111, which allows displaying the measured internal value

*The default is 0000, the battery voltage is displayed in the project clock for 
measuring voltage

SPEC NO.14

SPEC NO.15

SPEC NO.16

SPEC NO.17

SPEC NO.18

0000: 0d

1000: 8d

0100: 4d

1100: 12d

0001: 1d

1001: 9d

0101: 5d

1101: 13d

0010: 2d

1010: 10d

0110: 6d

1110:14d

0011: 3d

1011: 11d

0111: 7d

1111:15d

【BIT 3/BIT 2/BIT 1/BIT 0】Allow overload to display the number of divisions

【BIT 3/BIT 2/BIT 1/BIT 0】Do not use

【BIT 3/BIT 2/BIT 1/BIT 0】Do not use

【BIT 3/BIT 2/BIT 1】Do not use

【BIT 3/BIT 2/BIT 1】Do not use

0: Allow

0: Display battery voltage

1: Forbid

1:  Displays  the  percentage  of 

battery power remaining

【BIT 0】Display measured internal values

【BIT 0】Display items for measuring voltage

*The default is 0000

SPEC NO.19

【BIT 3/BIT 2/BIT 1/BIT 0】Do not use

Note: 
1. Set the unused setting bits to "0"
2. FS is full weighing value
3. The system function is used to define the setting of measurement 
specifications. The user cannot change it by himself, and it must be set by a 
professional technician.

  4.1 

  Full scale calibration

Modify BIT 3 of SPEC 12 to "0"

Click [REZERO] button to save

Click the switch below the scale body to open the calibration

Turn on the calibration switch again. Long press [REZERO], 

click [ ← ] [ ↑ ] [ ↑ ] to enter the calibration, display the 

maximum weight of calibration

REZERO

+

REZERO

UNIT

TARE

TARE

3. EDIT SETTINGS

3.5 System function definition

4.1 Full scale calibration

4. CALIBRATION OPERATION

*The default is 0101, the resolution is 3000d

1000: 6000d

1100: 15000d

1001: 7500d

1101: 20000d

1010: 10000d

OTHERS

1011: 12500d

Not used

SPEC NO.13

0000: 1000d

0100: 2500d

0001: 1250d

0101: 3000d

0010: 1500d

0110: 4000d

0011: 2000d

0111: 5000d

【BIT 3/BIT 2/BIT 1/BIT 0】Resolution selection

Содержание DSW-100 Series

Страница 1: ...DSW 100 SHANGHAI DIGITAL BALANCE ELECTRONIC CO LTD version1 4 2020 12...

Страница 2: ...eatures through this manual DSW 100 has weighing and counting functions Backlit display with automatic energy saving mode In addition the brightness of the backlight and the auto off time are set by t...

Страница 3: ...ons Make sure that one scale uses a matching power outlet Do not insert metal or flammable objects at the interface to avoid damage to the machine or fire If the scale falls please turn off the switch...

Страница 4: ...th and wipe with a detergent Do not use thinner or other volatile solvents In order to ensure the normal use of the scale before starting the operation every day adjust the level and lock the foot nut...

Страница 5: ...hen the weight is locked HOLD the indicator lights It is the operation confirmation and data save button in the setting mode and the zero operation button in the weighing mode Host power switch exit s...

Страница 6: ...o exit the field check and enter the weighing mode 2 When the battery capacity indicator shows only one frame it means that the internal battery voltage is too low please replace the battery Please us...

Страница 7: ...the heavy object which shows 0 500kg Method 2 Unplug the AC power and shut down Click REZERO again to reset to zero ON OFF Note When charging is not required unplug the AC power Note 1 If the placed w...

Страница 8: ...pressing the tare key 2 The peeling range can be modified by SPEC 04 BIT 0 to select the allowed peeling range of 50 FS or 100 FS TARE 1 Ensure that the scale is in a stable state 2 Press and hold th...

Страница 9: ...ase the number of objects placed on the weighing pan Make sure the scale is stable 1 Press and hold the key for 5 seconds to enter the weighing mode If there is already weight on the weighing pan when...

Страница 10: ...the weighing pan such as 0 545kg Click the key it is displayed as 1 202lb click the key again it is displayed as 19 22oz the third click the key it is displayed as 545g the fourth time it is restored...

Страница 11: ...quick operations you need to hold down the REZERO key for a long time while pressing other keys 2 Before restoring the factory SPEC settings you need to open the calibration switch at the bottom of t...

Страница 12: ...rmat setting 00 Generalcommandresponsemethod 10 POS ECR communication method 01 Simplecommand A responsemethod 11 Continuousweightdataoutputmethod The default is 1000 the RS 232 USB communication mode...

Страница 13: ...cremental key and increases 1 from right to left After the operation click REZERO to save and enter the next item click ON OFF to exit without saving REZERO ON OFF 3 5 System function definition SPEC...

Страница 14: ...interval onlyforfixmode1 SPEC NO 11 SPEC NO 12 000 No decimal point 100 Four decimal places 00 0000 001 One decimal 00000 0 101 Five decimal places 0 00000 010 Two decimal places 0000 00 011 Three dec...

Страница 15: ...BIT 0 Display items for measuring voltage The default is 0000 SPEC NO 19 BIT 3 BIT 2 BIT 1 BIT 0 Do not use Note 1 Set the unused setting bits to 0 2 FS is full weighing value 3 The system function i...

Страница 16: ...witch SPAN SW must be on 4 2 Full scale rate correction Click REZERO button to save Click the switch below the scale body to open the calibration Put a heavy object on the weighing platform such as 10...

Страница 17: ...F key to directly exit the calibration mode and return to the weighing mode 2 The calibration switch SPAN SW must be turned on 3 Calculation of the new standard rate Actual weight W1 10 00kg Display w...

Страница 18: ...storing the modified values of BIT 3 Spec 10 BIT 0 Spec 09 Spec 11 Spec 12 Spec 13 Coding Coding SPEC00 SPEC01 SPEC02 SPEC03 SPEC20 SPEC21 Defaults Defaults 1100 0100 0100 1011 1100 0000 SPEC04 SPEC05...

Страница 19: ...ata 8bit Stop 1bit no parity SPEC 21 0XXX The output data is synchronized with the display data when there is weight unit conversion SPEC 21 1XXX The output data is not synchronized with the display d...

Страница 20: ...H LSB 0DH Note 1 All characters are printed in ASCII code Contains only the numerical symbol the net weight value and the ending character CR 0DH with the higher value coming first When the value is n...

Страница 21: ...are both possible 2 When using this command method to obtain weight data the output data format includes the weight unit and after the weight unit is converted the numerical output will be based on t...

Страница 22: ...N 4EH 60lb E 45H 6kg C 43H 10kg I 49H 15kg A 41H 20kg J 4AH 25kg P 50H 30kg B 42H 60kg O 4FH 7 SERIAL AND USB 7 3 Standard serial port protocol 7 2 4 TYPE 2 INTERFACE Discontinual RS 232C Interface S...

Страница 23: ...ys 1 0 0 0 0 0 0 B2 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 7 SERIAL AND USB 7 3 Standard serial port protocol ii Simplified Status Codes iii Serial Communication 9600 Baud rate 7 Data bit Eve...

Страница 24: ...z 1000oz X XXX X XXX XX XXX XX XXX XXX X XXX X XXX X XXX X XX XXX XXXX X XX XX XX XX XX XX XX XX XX XX XX XX 5kg 6kg 10kg 20kg 30kg 7 SERIAL AND USB 7 3 Standard serial port protocol 7 2 7 TYPE 6 INTE...

Страница 25: ...0x2E This type efficiency NET WEIGHT data length is 7 digital With decimal point S FIX WORD 0x2B Weight is positive valve 0x2d Weight is minus value D 0x44 RS_CR 0x0d RS_LF 0xoa 3 Serial Communication...

Страница 26: ...Add No 788 Songxiu Road Qingpu Industrial Park Shanghai 201703 P R China Tel 0086 21 59757333 Tax 0086 21 69758587 Http www dbscale com cn version1 2 2020 6 version1 3 2020 8 version1 4 2020 12...

Отзывы: