33
32
[SW2] and [SW3]
Ex1. The NET WEIGHT is -124.50kg
The data format is 0x02,0x7c,0x59,0x70,0x30,0x31,0x32,0x34
,0x35,0x30, 0x30,0x31,0x32,0x34,0x35,0x30,0x0d.
7.1.5.4 Special data type 4 TERAOKA SCALES TYPE
DIGI RS232 Communication type.
SPEC SET: SPEC02 =11X1 ,SPEC 20= 1100,SPEC 21= XXXX
The mode efficiency NET WEIGHT data length is 7 digital With
decimal point & with stable word .
STABLE word 0x30 (30H)= STABLE , 0x31(31H) = UNSTABLE
RS_CR
0x0D (0DH)
RS_LF
0x0A (0AH)
Note 1: The above setting value 'X' is the bit that does not
affect this mode of operation, (0/1 is ok)
Note 2: No weight unit symbol. When weight is converted, the
value output is the value of the unit of weight set at the time of
calibration.
Ex1. The NET WEIGHT is -124.50kg (The negative weight
display function spec06.bit3,2=10 has been set)
The data format is 0x30,0x2d,0x31,0x32,0x34,0x2e,0x35
,0x30,0x0d,0x0a
Ex2. When NET WEIGHT is overload. (Weight overload)
The data format is 0x30,0x20,0x20,0x20,0x20,0x20,0x4F,0
SPECIAL DATA TYPE
7.2
SPECIAL DATA TYPE
7.2
7. SERIAL AND USB
7. SERIAL AND USB
3XH,3XH(LSB),0DH
7.1.5.2 Continuous data output, special format 2 (Special data
type 2)
SPEC SET: SPEC02 =11X1, SPEC 20= 0100, SPEC 21= XXXX
DATA FORMAT. 3XH(MSB),3XH,3XH,3XH, 2EH("."),3XH,3XH(LSB),
0DH
Note 1: All characters are printed in ASCII code. Contains only
the numerical symbol, the net weight value, and the ending
character CR(0DH), with the higher value coming first. When
the value is "negative", the highest bit output is 2EH(" - "). The
numeric fields are 7-byte (ASCII) characters.
Note 2: No weight unit symbol. When weight is converted, the
value output is the value of the unit of weight set at the time of
calibration.
For example: 1. The weight value of 2.56,
The output data: 30H, 30H, 30H, 32H, 2EH, 35H, 36H, 0DH
2. The weight value of -2.56,
The output data: 2DH, 30H, 30H, 32H, 2EH, 35H, 36H, 0DH
7.1.5.3 Continuous data output, Special data type 3 (TOLEDO
SCALES TYPE)
SPEC SET: SPEC02 =11X1 ,SPEC 20= 1000,SPEC 21= XXXX
No decimal point command. Total has 17 digital ASCII code.
[STX] WORD ASCII START FLAGE (02H) , [CR] WORD ASCII (0DH)
STATE WORD ,[SW1]
STATE WORD 1
BIT 0,1,2
BIT 0
BIT 1
BIT 2
DECIMAL POINT POSITION
DISPLAY SUBBSECTION
BITS 3
BITS 4
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
XXXXX0
XXXXXX
XXXX, X
XXX. XX
XX. XXX
X1
0
0
0
BITS 5
BITS 6
BITS 7
1
1
1
0
X2
X5
=“1”
=“1”
=“0”
SW 2 STATE WORD 2
SW 3 STATE WORD 3
BITS
BITS
FOUNCTION
FOUNCTION
GROSS =”0”, NET =”1”
NEGTIVER =”1” positive=”0”
Stable=”1”,Not stable“0”
W e i g h t U n i t :
g=”00”,kg=”01”lb=”10”,
once=”11”
OVER FULL =”1”,NOMRA=”0”
0
0
1
1
“1”
“0”
=“0”
=“0”
=“0”
=“0”
=“0”
=“1”
=“1”
=“1”
2
2
3
3
4
4
5
5
6
6
7
7
STX
NET WEIGHT
TARE WEIGHT
SW 1
SW 2
SW 3
CR
STABLE WORD
NET WEIGHT TEXT (With decimal point) + RS_CR + RS_LF
CR
NET WEIGHT(XXX.XXX)