21
Operating salt range:
3,000ppm – 36,000ppm
Ideal salt range:
4,500ppm – 6,000ppm
Low salt alarm:
~ 3,000ppm
Low salt cut-out:
~ 2,500ppm
Cooling:
Passive – product must be mounted on a flat vertical surface
using the supplied mounting kit to ensure adequate ventilation
Electrolytic cell type:
Coated Titanium, reverse polarity
Maximum water temperature (in cell):
45°C, or 113°F
Keep water below 30°C, or 86°F for chlorine effectiveness
Minimum recommended water
temperature (in cell):
15°C, or 59°F
Minimum flow (through cell):
COMM 500
COMM 1000
170L/min, 45USG/min, or 10.2m
3
/h
235L/min, 62USG/min, or 14.1m
3
/h
Head loss @ 350L/min
COMM 500
COMM 1000
8kPa, 1.16psi
13.2kPa, or 1.9psi
Pipe connections:
3
"
/ 80mm, or 2
"
/ 50mm with adaptors
Approvals:
EN60335-1, EN62233, EN61000-6-3, EN61000-3-2, EN61000-
3-3, EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-11, EN55014-2, IPX4
Dimensions of power supply enclosure
Height
Width
Depth
Mounting
Weight
COMM 500
COMM 1000
Inches
15.7
11.8
5.9
4 holes
W: 13.4
H: 12.8
28.7lb
28.7lb
Millimeters
400
300
150
4 holes
W: 340
H: 326
13kg
13kg
Dimensions of electrolytic cell housing
Height Width Depth
Inlet / outlet
(actual ID)
Plumbing holes
(from center to center)
Weight
COMM 500 COMM 1000
Inches
8.1
16.3
5.0
3.5
11.8
6lb
8lb
Millimeters
206
415
127
89
300
2.7kg
3.6kg
NOTE: In certain installations, these minimum flow rates may be insufficient to fill the cell housing
completely with water. In these cases, the flow must be increased to ensure that the cell plate
surfaces are completely immersed. Otherwise, damage will occur and decreased cell life will result.