Mains power connection
The power supply has a power cord attached to the bottom panel. The power cord should be connected
to mains power using the correct sized male plug or by hardwiring straight into the control box. The earth
must be connected. The GPO (General Purpose Outlet) / pool equipment control box, to which the unit
is connected should be protected by a Residual Current Device (RCD Safety Switch), see local electrical
regulations. The electrical supply to the unit should be interlocked to the main pump(s). That is, if the main
pump(s) are not operational, power is turned off.
External control connection
The external control feature is a means of controlling the EcoMatic chlorinator’s output from an external
controller. This can take the form of a timer, residual chlorine controller, or ORP monitor. The production
LED’s will light up to show that the external controller has the cell power turned ON.
The external control input requires normally open (NO), voltage free contacts, where open contacts
signal the chlorinator output is OFF and closed contacts signal the chlorinator output is ON. The external
controller’s output is connected to the terminals located at the base of the chlorinator as shown on page 7.
OPERATION
Start-up procedure
Ensure water flow through cell housing is above recommendations, see page 20. The production indicator is
a meter made up of a bar of five LEDs in the middle of the control panel.
Normal cell operation is indicated by five green LEDs being on.
The unit is fitted with an electronic control and warning system. This regulates the output of the Unit to a
preset maximum. The warning system consists of an OPERATION LED which will glow Red to indicate
possible faults with the Unit or damaging operating conditions.