Connection of the condensate drainage kit:
3.3 Features
a. DC Twin-rotary inverter compressor of Mitsubishi
b. DC Brushless fan motor
c. EEV Technology
d. Reverse cycle defrosting with 4-way valve
e. High-efficiency twisted titanium heat exchanger
f. Sensitive and accurate temp control and water temp display
g. High pressure and low pressure protection
h. Full protection on electrical systemea
3.4 Operating Range
To get the best results from your Davey heat pump please set swimming pool water temperature efficiently
and economically.
The heat pump can operate in temperatures between -10°C – 43°C, and its ideal operation range is
between air 15°C – 25°C.
During installation and operation of the Davey heat pump, its important to ensure that the flow rate in set to
the advised water flow rate in section 3.6 and that the pressure does not exceed 500kPa.
In accordance with AS/NZS 60335.2.40 we are obligated to inform you that this Davey
heat pump is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience or knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
3.5 Introduction of different modes
The heat pump has two modes: Boost and Silence.
They have different strengths under different conditions.
MODE
MODES
STRENGTH
Boost mode
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fast heating
Silence mode
Heating capacity: 20% to 80% capacity
Sound level: 3dB (A) lower than Boost mode