background image

25

Davey Heat Pump

DHP90

DHP130

DHP170

DHP210

DHP280

DHP3503

ITEM

PART NO.

DESCRIPTION

NOTE

QTY

REQ’D

1

403759

DHP130 PC board

1

1

403817

DHP170 PC board

1

1

403818

DHP210 PC board

1

1

16302

DHP280 PC Board 

1

1

16303

DHP3503 PC Board 

1

1

403758

DHP90 PC board

1

2

403760

Round touch controller

1

3

403762

Inverter board DHP130

1

3

403819

Inverter board DHP170

1

3

403820

Inverter board DHP210

1

3

16306

Inverter Board DHP280

1

3

16307

Inverter Board DHP3503

1

3

403761

Inverter board DHP90

1

5

403764

Reactor DHP130

1

5

403763

Reactor DHP90

1

8

403766

Power fi lter board DHP130

1

8

403821

Power fi lter board DHP210

1

8

16309

Power Filter Board DHP280

1

8

16310

Power Filter Board DHP3503

1

8

403765

Power fi lter board DHP90

1

10

403767

Electronic expansion valve

1

11

403768

4-way valve

1

12

403769

Water fl ow switch

1

13

403770

Fan motor DHP90/DHP130

1

13

403822

Fan motor DHP170/DHP210

1

13

16311

Fan Motor DHP280

1

13

16312

Fan Motor DHP3503

1

14

403771

Sensors (full set)

1

16

16294

R32 Compressor DHP130

1

16

16296

R32 Compressor DHP170 210

1

16

16304

R32 Compressor DHP280

1

16

16305

R32 Compressor DHP3503

1

16

16292

R32 Compressor DHP90

1

17

16295

Titanium heat exchanger DHP130

1

17

16297

Titanium heat exchanger DHP170

1

17

16298

Titanium heat exchanger DHP210

1

17

16315

Titanium Heat Exchanger DHP280

1

17

16316

Titanium Heat Exchanger DHP3503

1

17

16293

Titanium heat exchanger DHP90

1

22

16299

Low pressure valve

1

23

403772

Union set 40mm (nut, tail, oring)

1

24

403773

Union gasket

1

25

403774

Fan blade DHP90/DHP130

1

25

403823

Fan blade DHP170

1

25

403824

Fan blade DHP210

1

25

16317

Fan Blade DHP280

1

25

16318

Fan Blade DHP3503

1

26

403775

Drainage kit

1

-

16308

Contactor DHP3503

1

-

403777

Screw kit for case (set)

1

-

403776

Screw kit for electrical box (set)

1

26

403775

Drainage kit

1

26

403775

Drainage kit

1

26

403775

Drainage kit

1

-

403776

Screw kit for electrical box (set)

1

-

403777

Screw kit for case (set)

1

SP0025-2/0921              

16

17

24
23

24

23

3

1

8

20

21

22

14

+

26

12

11

10

5

18

2

25

13

16

17

24
23

24

23

3

1

8

20

21

22

14

+

26

12

11

10

5

18

2

25

13

11. SPARE PARTS

Содержание DHP90

Страница 1: ...Please pass on these instructions to the operator of this equipment Pool Heat Pump Installation and Operating Instructions...

Страница 2: ...ANCE 7 4 1 Installation reminder 7 4 2 Wiring 9 4 3 Electric wiring diagram 9 4 4 References for protecting devices and cable specification 9 5 OPERATION GUIDANCE 10 5 1 Key function 10 5 2 Operation...

Страница 3: ...appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour R32 Gas INSTALLATION REMINDERS The installation of any pipework should be kept to a...

Страница 4: ...r outage happens during operation the heat pump will start when the power is restored c Please switch off the main power supply in lightening and storm weather to prevent from damage caused by lightni...

Страница 5: ...ortant to ensure that the flow rate in set to the advised water flow rate in section 3 6 and that the pressure does not exceed 500kPa In accordance with AS NZS 60335 2 40 we are obligated to inform yo...

Страница 6: ...0 19 1 38 0 26 1 80 0 33 2 50 0 38 2 90 0 49 3 80 0 65 4 84 Input power at 50 speed kW 0 51 0 7 0 95 1 1 1 44 1 84 Rated input current A 0 83 5 98 1 13 7 83 1 44 10 90 1 66 12 7 2 15 16 53 0 95 7 01...

Страница 7: ...his heat through its heat exchanger to the pool water Your Davey heat pump should be installed in a well ventilated area WARNING Improper installation adjustment service maintenance or use can cause f...

Страница 8: ...fastened the bracket must be strong enough and antirust treated 2 Please ensure 50cm of clearance around each side of the Davey heat pump or the efficiency of the heat pump will be reduced 3 Although...

Страница 9: ...full disconnection of the power supply must be incorporated in the fixed wiring in accordance with the wiring rules 4 3 Electric wiring diagram a For power supply 230V 50Hz Distribution Box Power Sup...

Страница 10: ...ark when it s locked 5 2 Operation Instruction a Screen Lock 1 Press for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation b Power On Press for 3 seconds to unl...

Страница 11: ...ss to exit status check mode SYMBOL CONTENT UNIT C0 Inlet water temp C C1 Outlet water temp C C2 Ambient temp C C3 Exhaust temp C C4 Outer coil pipe temp C C5 Gas return temp C C6 Inner coil pipe temp...

Страница 12: ...to occur to the Davey heat pump a Turn off the circuit breaker or isolation switch b Drain the Davey heat pump Loosen all water connections c Rinse the interior of the heat exchanger cylinder with a...

Страница 13: ...avoided The area around the workspace should be sectioned off Ensure that all conditions within the area have been made safe by control of flammable material 3 Always check the work area with an appr...

Страница 14: ...chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed or extinguished If a leakage of refrigerant is found which requires b...

Страница 15: ...outlet water Insufficient water flow protection 4 Eb Ambient temperature too high or too low protection 5 Ed Anti freezing reminder No Display Failure Code Description 1 E1 High pressure protection 2...

Страница 16: ...mperature difference then either restart the heat pump or go back into standby The default setting is P2 To change these parameters please contact your nearest Davey dealer verter heat pump solution I...

Страница 17: ...V 50Hz Customer prepare Power Supply 230V 50Hz Earthing Water pump 230V voltage 500W capacity Breaker fuse Customer prepare Breaker fuse Customer prepare Contactor Powercord 17 Customer remote control...

Страница 18: ...18...

Страница 19: ...nt Registration Register by e mail or third party application Android iOS a E mail registration Android please download from iPhone please download from 1 APP Download 2 Account registration 1 Registe...

Страница 20: ...20 Please set family name and choose location of device Create Family b Register through third party application...

Страница 21: ...21 APP Pairing a With Bluetooth 1 Please confirm that you re connected to Wi Fi and your Bluetooth is on 2 Click Add Device and then follow the instructions to pair device...

Страница 22: ...d release After hearing Beep enter Wi Fi password in app During connection will flash Once the app connects to Wi Fi successfully will display b With Wi Fi 1 Please make sure you are connected to Wi F...

Страница 23: ...r On Off Setting temperature Select Boost Silence Mode 2 For heat pump with Heating Cooling function Compressor speed Query C F switch Setting temperature Select Boost Silence Mode Compressor speed In...

Страница 24: ...ather forecast is just for reference 2 App is subject to updates without notice After pairing if your family members also want to control the device please let your family members register InverGo fir...

Страница 25: ...tor DHP3503 1 14 403771 Sensors full set 1 16 16294 R32 Compressor DHP130 1 16 16296 R32 Compressor DHP170 210 1 16 16304 R32 Compressor DHP280 1 16 16305 R32 Compressor DHP3503 1 16 16292 R32 Compres...

Страница 26: ...26 NOTES...

Страница 27: ...27...

Страница 28: ...their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions...

Отзывы: