background image

 

 

Warnings and Precautions

 

1.

 

Read all of these warnings and save them for later reference. 

2.

 

Follow all warnings and instructions marked on this unit. 

3.

 

Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp 

cloth for cleaning. 

4.

 

Do not use this unit in or near water.

 

 

5.

 

Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing serious damage. 

6.

 

Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To ensure safe 

and reliable operation of this unit, and to protect it from overheating, do not block or cover these 

openings. Do not place this unit on a bed, sofa, rug, or similar surface, as the ventilation openings on 

the bottom of the cabinet will be blocked. This unit should never be placed near or over a heat register 

or radiator. This unit should not be placed in a built-in installation unless proper ventilation is provided. 

7.

 

This product should only be operated from the type of power source indicated on the marking label of 

the AC adapter. If you are not sure of the type of power available, consult your Datavideo dealer or 

your local power company. 

8.

 

Do not allow anything to rest on the power cord. Do not locate this unit where the power cord will be 

walked on, rolled over, or otherwise stressed. 

9.

 

If an extension cord must be used with this unit, make sure that the total of the ampere ratings on the 

products plugged into the extension cord do not exceed the extension cord rating. 

10.

 

Make sure that the total amperes of all the units that are plugged into a single wall outlet do not 

exceed 15 amperes. 

11.

 

Never push objects of any kind into this unit through the cabinet ventilation slots, as they may touch 

dangerous voltage points or short out parts that could result in risk of fire or electric shock. Never spill 

liquid of any kind onto or into this unit. 

12.

 

Except as specifically explained elsewhere in this manual, do not attempt to service this product 

yourself. Opening or removing covers that are marked “Do Not Remove” may expose you to dangerous 

voltage points or other risks, and will void your warranty. Refer all service issues to qualified service 

personnel. 

13.

 

Unplug this product from the wall outlet and refer to qualified service personnel under the following 

conditions: 
a.

 

When the power cord is damaged or frayed; 

b.

 

When liquid has spilled into the unit; 

c.

 

When the product has been exposed to rain or water;  

d.

 

When the product does not operate normally under normal operating conditions. Adjust only those 

controls that are covered by the operating instructions in this manual; improper adjustment of 

other controls may result in damage to the unit and may often require extensive work by a 

qualified technician to restore the unit to normal operation; 

e.

 

When the product has been dropped or the cabinet has been damaged; 

f.

 

When the product exhibits a distinct change in performance, indicating a need for service. 

 

 

 

Содержание SE-1200MU

Страница 1: ...1...

Страница 2: ...the SE 1200 MU from another building or city 14 3 2 3 Setting the Target IP Address with the Controller Software 15 Chapter 4 SE 1200 MU Video Setup 17 4 1 SE 1200 MU Multi View Output 17 4 2 Setting...

Страница 3: ...FTB Key Function 30 6 4 1 Enable 30 6 4 2 FTB 30 6 5 DSK TRANS Panel 30 Chapter 7 Applications 31 7 1 Luma Key Quick DSK 1 Setup 31 7 1 1 Keyer Control 32 7 1 2 Keyer Matte 33 7 2 Linear key Quick DSK...

Страница 4: ...his instruction manual is intended as a guide only At all times Datavideo Technologies will try to give correct complete and suitable information However Datavideo Technologies cannot exclude that som...

Страница 5: ...hat the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a...

Страница 6: ...a free one year extension to the standard Warranty providing the product is registered with Datavideo within 30 days of purchase For information on how to register please visit www datavideo com or co...

Страница 7: ...AM 100 or AD 200 Tally and RJ 45 connections allow the switcher to be connected to a Windows PC as well as providing tally light indications to crew and on screen talent via Datavideo s ITC 100 talkb...

Страница 8: ...8 1 2 System Diagram...

Страница 9: ...T HDMI 1 and the two SDI outputs can be used for monitoring video in a number of different configurations including Program Preview and or Multi view See Section 4 2 HDMI 2 Multi view Output ONLY Note...

Страница 10: ...d Amber Red indicates On Air and Amber indicates next camera source DC IN Connect the supplied 12V 19W PSU to this socket The connection can be secured by screwing the outer fastening ring of the DC I...

Страница 11: ...ernet cable The following set up should allow you to initially configure the unit before moving it to an existing DHCP LAN network An RJ 45 ethernet cable Windows 7 8 laptop or PC The Datavideo SE 120...

Страница 12: ...re The SE 1200 MU controller software has a built in IP finder which is designed for PC with multiple Ethernet cards or DHCP network environment Please note IP finder can only find devices that are on...

Страница 13: ...he assistance of your local I T specialist to help with the network settings To help guide you we have included a simplified network set up example below further advice may be available through your d...

Страница 14: ...3 The computer because it is set for DHCP will already have an IP address automatically assigned to it in this list 14 The SE 1200 MU may only show its MAC address 1E ED 19 27 1A B3 Copy and Paste the...

Страница 15: ...l from site B The Public IP address for site A needs to be discovered this will be used as the Target IP address for both VLC player and the SE 1200 MU Controller software at site B 3 2 3 Setting the...

Страница 16: ...ions on the SE 1200 MU When delivered from the factory the default static IP settings should be Set up Static a manually set IP address that does not change even after power cycling the SE 1200 MU uni...

Страница 17: ...gram PGM Inputs 1 6 as well as SDI outputs 1 and 2 The SE 1200 MU can also show audio level bars overlaid on the Program image within the multi view This confirms if analogue XLR audio input is being...

Страница 18: ...U HDMI multi view output only operates at the 1080P or 720P standards This can be useful for some HDMI and DVI monitor types If an interlaced 1080i Multi view output is needed please configure an SDI...

Страница 19: ...displayed in the background video layer If set up incorrectly these key layers can stop the video behind being displayed The Picture in Picture PiP feature of the Key 1 Key 2 layers can be used for di...

Страница 20: ...saved as user setups in the shot box area of the software control interface for quick and easy recall Copyright Most broadcast networks have guidelines and advice on the use of video images music log...

Страница 21: ...iew label should now be displayed Note The label will accept up to 16 characters but only the first 10 are displayed A Freeze option is provided for use when you wish to grab and save a still image fr...

Страница 22: ...ize of the multi view being streamed Options are Full Half Quarter and Sixth By choosing HALF instead of FULL you are using less bandwidth to support the multi view stream being sent across the IP net...

Страница 23: ...the IP network The quality of the multi view image will also be affected by these settings The VLC media player window with SE 1200 MU multi view can be displayed on a second computer monitor using t...

Страница 24: ...ve ON then the selected AUX button will be backlit red 6 1 2 PROGRAM This row of buttons is typically used to select sources or images for the SE 1200 MU main Program output The currently selected sou...

Страница 25: ...view outputs but has not been shown on the Program output NOTE Remember to disable the Trans Pvw button before attempting to use the selected transition on the live Program output 6 2 2 Rev and Nrm NO...

Страница 26: ...t row of buttons and then pressing the Cut button 6 3 2 Mixing between Sources In order to mix between two video sources first ensure the Background Transition or Bgnd button is ON backlit green in th...

Страница 27: ...to the selected next source on the Preset row To change the rate of transition for the Auto button press the Home menu button and change the M E Trans duration value in frames If this M E Trans value...

Страница 28: ...centre position of some wipes e g Circle Elipse Options in the lower blue row Wipe allows a wipe pattern to be selected by entering the required wipe number Soft allows the user to blend the leading a...

Страница 29: ...Delete Clip function is available in the clip menu Progress Dialog on Clip Load gives the user an idea where the load is currently at It can be cancelled at any stage even before the load is complete...

Страница 30: ...lected DSK button is green it is on and the active DSK result is seen in the multi view Preview video image Each DSK button has an LED above it This LED can also be off or on Green When the selected D...

Страница 31: ...n on the AUX BUSES panel Step 2 Choose the type of Keyer you want to use In our example we will click the Luma button on the KEYER CONTROLS panel Step 3 Select the foreground video source to be keyed...

Страница 32: ...the Auto button in the DSK TRANS panel AUTO TRANS ACTIVE ON PGM 7 1 1 Keyer Control Lift Adjusts the dark black areas in the key image Gain Adjusts the light white areas in the key image Opacity Adju...

Страница 33: ...The Hue value or angle can be adjusted by clicking on the Hue value and using the pop up keypad Certain colour hues can be found at certain angles on the colour palette For example Red is 0 degrees 1...

Страница 34: ...CG Fill source on AUX BUS Row input2 DSK OFF PVW ACTIVE Step 5 To see the current keying effect on the Multi view Preview image only click on the DSK 2 PVW button in the DSK TRANS panel so it becomes...

Страница 35: ...Key 2 button for our PIP image Step 2 Select the Key 2 effect by clicking the P in P button backlit green in the Keyer Controls panel Step 3 Turn the Key 2 PIP effect on in the Multi view Preview out...

Страница 36: ...d 0 5 reduces the PiP size to half screen 50 Click and hold the joystick circle then drag the joystick circle in the desired direction Left mouse button Joystick dragging allows the PiP to be moved in...

Страница 37: ...ing the value makes the border thicker but less of the selected PiP image will be seen 7 3 3 PIP Crop The PiP Crop values are displayed along the bottom of the screen as shown below The Left Right Top...

Страница 38: ...an be finely adjusted by clicking on the Sat value and entering a new value If the Hue angle is set to 180 degrees 6 o clock position then the Sat value determines how much Cyan is in the matte 7 The...

Страница 39: ...E 1200 MU format pic files All you need is to give the PC control APP a starting file location and it will give the PC control APP an idea where to start linking all images up into a sequential animat...

Страница 40: ...ersion the clip import will then start After the import is complete the progress dialog will be automatically closed Note The Clip Conversion and Clip Import have progress dialogs that show progress n...

Страница 41: ...tudio The camera must be correctly white balanced to minimize the subject picking up any colour cast green or blue from the background Of course the white balance settings will vary according to the t...

Страница 42: ...egree value in the lower bar and entering the required number Certain colour hues can be found at certain angles on the colour palette For example Red is 0 degrees 12 o clock position Green is around...

Страница 43: ...lying more Key Gain may help depending on the setup of the green or blue screen studio This value can be fine tuned up or down by changing the Key Gain value 8 4 Color Spill The Color Spill parameters...

Страница 44: ...yer you want to use in KEYER CONTROLS panel In our example we have clicked the Chroma button on the KEYER CONTROLS panel Step 3 Select the foreground video source with the subject or talent to be keye...

Страница 45: ...e whole foreground shot It is also helpful if only a small area of the foreground image is being Luma keyed say a whiteboard or blackboard Each mask value is based on a percentage of the screen width...

Страница 46: ...ers will then be displayed along the bottom row of the screen Click on the Live Mode option and then select the Freeze option from the pop up menu list When Freeze is clicked here the video is immedia...

Страница 47: ...select the input channel to be used for displaying the saved still image This will also place that input channel onto the Preview window in the SE 1200 MU Multi view Do not worry if at this stage it i...

Страница 48: ...lternatively enter the Still value and then click Load Still 6 The input channel will now display only the selected still image To change the still to another follow step 5 again To return the input c...

Страница 49: ...the computer within the following folders C Datavideo se1200 user_data Exported Still picture files can be found in the export based stills folder see opposite For each image exported there will be tw...

Страница 50: ...MU 10 1 Saving the Current Settings to a User Memory Slot 1 First set up and configure the SE 1200 MU with the settings that you would like to keep for future use 2 Click the User button on the MENU S...

Страница 51: ...bel 3 Click Name in the lower row menu options an on screen keyboard will be displayed Enter a label name for the selected user memory slot The label text can be up to 16 characters long but only the...

Страница 52: ...ser setup is one of the first 8 memory slots then simply click the corresponding button on the USER SHOT BOX panel 2 A second way to do the same thing is to enter the USER option on the MENU SELECT pa...

Страница 53: ...ser Memory click Delete Memory located at the bottom of the screen 10 5 Exporting and Importing User Setups A previously saved SE 1200 MU User memory can be exported from the unit to the User s comput...

Страница 54: ...n exported from the SE 1200 MU are stored on the computer in the following folders C Datavideo se1200 user_data Exported User files can be found in the export based mems folder see opposite Prepared U...

Страница 55: ...elates to the preferred audio standard for the user A choice of SMPTE or EBU is given Note Audio is not supplied with the IP streamed multi view Local SDI and HDMI outputs can provide the audio Append...

Страница 56: ...tic IP set up see example on Section 3 2 1 Firmware Update Procedure 1 Install the latest SE 1200 MU Control Panel program on the Windows PC Laptop 2 Locate the Ethernet port on the rear panel of the...

Страница 57: ...57 Appendix 4 Dimensions All measurements in millimetres mm...

Страница 58: ...r on Multi view Y output 2CH Tally Out Y GPI Y Level Pulse Trigger selectable Software Updates Ethernet Standards HD Format Support 1080i 50 1080i 59 94 1080i 60 720p 50 720p 59 94 720p 60 SDI Complia...

Страница 59: ...3 Still frames stored in local frame buffers for instant access Control Panel Compatibility Use PC via Ethernet Control panel Input Voltage 12V Power consumption 23W Control Protocol DVIP Multi View M...

Страница 60: ...60 Service and Support...

Отзывы: