SCS1
Series
Instruction
Manual
4
2. ELECTRICAL CONNECTION
M12 connector
2
8
1
5
3
4
7
6
+ 24 Vdc
GND
OUTPUT 2
EXTERNAL TRIGGER
RS232 TX / RS485 - /
INPUT1
OUTPUT 1
CONFIGURABLE
INPUT
RS232 RX / RS485 + /
INPUT2
1 = white
= RS232 TX / RS485 -/ Input1
2 = brown
= 24 Vdc power supply
3 = green
= Configurable input
4 = yellow
= Output 1
5 = grey
= Output 2
6 = pink
= RS232 RX/ RS485 +/ Input2
7 = blue
= GND
8 = red
= External trigger signal input
M8 connector
3
1
4
2
Strobe
GND
N.C.
+24Vdc
1 = brown = 24
Vdc
2 = white
= Not
connected
3 = blue
= GND
4 = black
= Strobe TTL signal
RJ45 connector
This connector is used for sensor and PC communication using Ethernet 10/100 Mbps network.
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]