SCS1
Series
Instruction
Manual
90
Note:
the main characteristics of the selected blob are visualised by clicking on the right mouse
button on the coloured area identifying a blob.
Positioning:
-
click on left mouse button to set the rectangle vertex;
-
drag the mouse (keeping button pressed) to set rectangle dimension;
-
release button to confirm;
-
the position and dimensions can be changed graphically.
Results:
-
barycentre coordinates of the blob with larger dimensions (“X”,”Y”);
-
relative reference system graphic representation with origin in the barycentre of the blob
with larger dimensions;
-
relative reference system angle (“Angle”);
-
status.
Parameters:
X, Y:
top left ROI coordinates.
Height:
rectangle height delimiting the ROI.
Width
:
rectangle width delimiting the ROI.
Object type:
specifies the blob type to locate:
-
black
object;
-
white
object.
Binarization threshold:
value of the threshold used to distinguish
light-coloured pixels from the dark ones during image passage
from greyscale in black and white.
Pixels with a value superior to the threshold result to be white after
binarizzation, those with an inferior value black.
The threshold is calculated automatically when the tools are
inserted.
To fix it manually, the user has to click on the icon on the left of
the numeric threshold value (
), then click on “Numeric Value”,
and the “A” disappears. The value of the “Threshold” can be now
changed.
Choosing again “Automatic” the device returns to the automatic
mode (the letter “A” has to appear in the box).
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]