Step 1 - “BAC”
Background acquisition. Press SET to acquire
background and to pass to next phase.
Step 2 - ”TARG”
Acquisition of the object to detect. Position the
sample in front of the sensor and press SET to
acquire it and pass to next phase.
Step 3 - “SUCC”/”FAIL”
According to the acquisition result, the SUCC or
FAIL text is visualised. In case of failure press
SET and return to main menu. In case of success
press SET to pass to next phase.
Step 4 - Threshold
Acceptance threshold regulation. The value
visualised represents the acceptance threshold
used during inspection. The lower the threshold,
the more the sample and imagine have to
correspond in order to obtain a successful result.
Use the + or – push-buttons to change the
threshold.
5.8. Teach-in
Self-setting process that allows the sensor to acquire the information relative to the target-object and
its background.
The Teach-in process follows the phases listed below:
During threshold regulation, the sensor outputs are activated. Practically, the same conditions of the
inspection running are present (
Run mode
), with however the possibility of changing the sensor
sensitivity to distinguish or not an object.
Once acquired the information relative to the target-object, the sensor recognises the object and
consequently the yellow Output 1 LED turns on, indicating inspection success.
The threshold can now be lowered until the LED turns off. The threshold has become so narrow that
even the target-object is no longer recognised. A safety margin can be thus established increasing the
threshold with respect to the constraint found.
The use of an integral target-object and a damaged one can allow the user to configure the threshold
in order to recognise the integral target-object from the damaged one.
Step 5 – Confirmation
Press SET to confirm the Teach-in sequence. The user returns automatically to the main menu. The
inspection can be saved by scrolling down the options until reaching
and selecting it. The
sensor enters automatically in
Run mode
. Otherwise select
to run the inspection.
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]