Instruction
Manual
SCS1
Series
45
5. SENSOR INTEGRATED USER INTERFACE
The sensor integrated user interface presents three push-buttons (SET, +, -), 4-digit display and 4
signalling LEDs.
-
the SET, + and – push-buttons are used for sensor configuration
-
the yellow LED indicates the sensor Output 1 status
-
the three green LEDs are connected respectively to (from left to right):
Output
2
External trigger
Configurable
input
5.1. Powering
At powering, the sensor enters in an initialisation phase that lasts for 25 seconds and then
automatically carries-out an inspection.
During initialisation, the display visualises the following texts:
SCS1:
INIT (boot):
5.2. Factory configuration reloading
During initialisation there is the chance to reload the factory configuration.
Press + and – push-buttons at the same time when the display visualises
text. Keep them
pressed until
text is visualised and then for 3 seconds at lest to start the factory configuration
reloading process. When the system reset is over, the display will visualise
text.
Output 1
Output 2
External
trigger
Configuration
input
- push-button
+ push-button
SET
push-button
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]