Instruction
Manual
SCS1
Series
63
Live mode parameters
Resolution:
VGA (640x480 pixels) and ¼ VGA (320x240 pixels)
resolutions are available.
Exposure time
: the duration of light exposure during the image
acquisition phase. The exposure time can be set both manually
(modifying the number corresponding to the duration in ms and
clicking on “Apply”) or automatically (clicking on “Autoexpose”).
The higher the exposure time, the brighter the image.
Gain:
electronic enhance of the image signal. Gain increases
image brightness without increasing exposure time. A larger gain
corresponds to major noise and consequently the image quality
decreases.
Note:
the lens presents two rings: one for shutter regulation and the other for focus. Between the
rings there is a white notch that acts as reference point. The focus ring is characterised by
“
near
” text and “
∞
” symbol. Turning the ring making closer the reference notch and
near,
the
sensor will progressively focus a closer plane. Turning the ring making closer the notch and
∞
,
the sensor will progressively focus a further plane.
Acquisition mode:
configures the reference image using the
trigger hardware, if set in the
trigger
mode. For example, if
a dynamic scene is controlled, a particular phase is difficult
to obtain by pressing the “
saving the reference image
” icon. The acquisition of the reference image
in the
trigger mode
and, using a trigger hardware, has to be set and then save the singular phases
of the inspected scene until reaching the necessary configuration. In this case, pressing “
saving the
reference image
” and providing another trigger pulse, a particular image can be saved as our
template.
Reference image:
the image used to configure inspection.
The image visualised on the window is saved by pressing “Set reference
image”. The image will be available during the Setup phase.
Advanced parameters
Illuminators
: an external illuminator can be activated or
deactivated. The strobe function can also be activated or
deactivated.
Trigger parameters
: parameters that refer to the external trigger
and that do not affect the
Continuous mode
and
Software
trigger
.
-
Minimum trigger pulse duration: short pulses due to
disturbances can appear and can be confused with
trigger signals. To avoid unwanted acquisitions, the user
can set a minimum trigger pulse duration and so shorter
pulses will not be considered.
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]