4. SENSOR CONFIGURATION
The term “inspection” refers to all the operations the sensor carries-out to control object characteristics
and control the respect of specific conditions.
The user has two possibilities to set correctly the sensor for inspection configuration:
-
sensor integrated interface;
-
SCS1 graphic interface.
4.1. General considerations
Some general conditions have to be respected when configuring an inspection:
-
decide exactly what to detect;
-
assure correct and constant lighting, minimising ambient light conditioning on working area;
-
assure a good contrast between target-object and background;
-
acquire a good reference image
.
The reference image is used as a template to determine the specifications to be respected by the
images acquired during the inspection.
It is thus very important to acquire a high-quality image, where the target-object presents well-defined
edges and evident main characteristics:
-
choose carefully the tools to use for the elaboration to guarantee the best result possible in the
easiest manner (particularly in the software inspection where a wider range of tools is available);
-
regulate precisely the parameters of the tools selected;
-
test the inspection choices made on different variations of the same object, trying to carefully
distinguish the constraints within which inspection results can be considered correct and which
tolerance can be accepted without passing the constraints;
-
compare results to discover any incongruence;
-
re-configure tools to reduce incongruence;
-
run
inspection.
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]